– 117 –
1-7. Thread breakage detector plate
1
2
3
1) Adjust so that thread breakage detector plate
1
is
always in contact with thread take-up spring
2
in the
absence of needle thread. (Slack : approx. 0.5 mm)
2) Whenever the stroke of thread take-up spring
2
has been changed, be sure to readjust
thread breakage detector plate
1
. To make this
adjustment, loosen screw
3
.
Adjust so that thread breakage
detector plate
1
does not touch
any adjacent metallic parts other
than thread take-up spring
2
.
1-6. Needle thread clamp device
1) When thread is caught
at top end
1
of the
thread clamp, thread
clamp becomes
incomplete and sewing
trouble at the sewing
start will be caused.
Periodically remove
and clean the throat
plate since waste
thread or thread dust
is apt to gather in the
places with circle mark.
1-5. The moving knife and counter knife
1.0 mm
18.5 mm
1) Loosen adjusting screw
1
so that a clearance
of 18.5 mm is provided between the front end
of the throat plate and the top end of thread
trimmer lever, small
3
. To adjust, move the
moving knife in the direction of arrow.
2) Loosen setscrew
5
so that a clearance of 1.0
mm is provided between needle hole guide
2
and counter knife
4
. To adjust, move the
counter knife.
Throat plate
1
2
5
4
3
1
1
WARNING :
Turn OFF the power before starting the work so as to prevent accidents caused by abrupt start of
the sewing machine.
WARNING :
Turn OFF the power before starting the work so as to prevent accidents caused by abrupt start of
the sewing machine.
Содержание AMS-210E-1306
Страница 1: ...i ENGLISH INSTRUCTION MANUAL ...