– 111 –
E802
E811
E813
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
the power.
E306
E307
E308
E703
E704
E730
E731
E733
Turn OFF
the power.
Possible
to re-start
after reset.
Turn OFF
the power.
Possible
to rewrite
program after
pressing down
communication
switch.
Possible
to rewrite
program after
pressing down
communication
switch.
Turn OFF
the power.
Turn OFF
the power.
Turn OFF
the power.
Data input
screen
Communication
screen
Communication
screen
Error code
Description of error
How to recover Place of recovery
Thread clamp position error
Thread clamp unit is not in the regular position.
External input command time out error
Input is not performed for a fixed period of time with
the external input command of vector data.
Time-out error of wait terminal
There is no input to wait terminal for a certain period
of time.
Panel is connected to the sewing machine which
is not supposed. (Machine type error)
When the machine type code of system is not proper
in the initial communication.
Inconsistency of system version
System software version is inconsistent in the initial
communication.
Main shaft motor encoder defectiveness
When encoder of the sewing machine motor is
abnormal.
Main motor hole sensor is defective or position
sensor is defective.
Hole sensor or position sensor of the sewing machine
motor is defective.
Reverse rotation of main shaft motor
When sewing machine motor rotates in reverse
direction.
Power electrical discontinuity detection
Overvoltage
When input power is more than the specified value.
Low voltage
When input power is less than the specified value.
Содержание AMS-210E-1306