Installation and operating instructions: JUDO UV disinfection system JUV 10-110 G/GS
All rights reserved.
JUDO Wasseraufbereitung GmbH
© JUDO Wasseraufbereitung GmbH
Postfach 380
D-71351 Winnenden
Translation into foreign languages and reproduction, even in excerpt form, is only permitted with special
approval.
Tel. +49 (0)7195-692-0
Fax +49 (0)7195-692-188
Revision level: 03.05.2017
E-mail: [email protected]
Internet: www.judo.eu
45
8
C a l i b r . T
0 0 ° C
Calibr.T
→ Calibrate temperature
Max. water temperature at which the system should switch off the
radiation chamber.
Setting 00 °C = Function disabled
or
Do not change setting:
Display switches to status display
7: Stop For
Display switches to status display
9: Exit Settings
or
Change setting:
Press Enter to call up the cursor.
C a l i b r . T
0 0 ° C
Press Enter to position the cursor and increase or decrease the
numerical value in °C by pressing the up and down keys.
Press Enter until you reach the end of the row and the cursor
disappears. Input is set.
Display switches to status display
9: Exit Settings
9
E x i t
S e t t i n g s
Exit Settings
→ Exit Settings menu
or
Do not exit Settings menu:
Display switches to status display
8: Calibr.T
Display switches to status display
2: On Delay
or
Exit Settings menu:
Press Enter.
Display switches to status display.
* Example for interval switching:
Given:
-
Current time, e.g. 16:00
-
Required deactivation time, e.g. 22:00
-
Required activation time, e.g. 06:00
Setting:
-
Stop IN
06 h
-
Stop For
08 h
Function:
The UVC lamp automatically switches off at 22:00, remains off for 8 hours and then switches back on again at 06:00
every day.