46
8.5
Exploded drawing dosing head
Fig. 17: Exploded drawing dosing head
8.5.1
Spare parts
Designation
Item
Order no. Pc.
Suction/pressure valves with diaphragms 1/3/4/9/10 1880026
1
Suction/pressure valves
4/9
1880027
1
Dosing head assembly
1-10
1880029
1
Dosing diaphragm
3/10
1880031
1
Suction/dosing pipes connection set
*
1880033
1
JUDO dosing hose JDS-T 6/4
**
8725106
1
Diaphragm pump with stepper motor
***
1980523
1
Suction kit, complete
***
1980524
1
JUDO cold water injection point
***
8340022
1
JUDO hot water injection point
***
8340036
1
Union nut hot water injection point
****
1610347
1
Tubular stiffener hot water injection point
****
1450041
1
Clamping ring hot water injection point
****
1450264
1
Tab. 26: Spare parts
*
Not shown (comprising union nut, clamping ring, insert with connecting cone)
**
Please specify the length required for the order in metres
***
Not shown
****
See Chap. 4.3.2
8.6
Transfer confirmation and maintenance log
The attached transfer confirmation must be carefully filled out upon commissioning!
The attached maintenance log must be carefully filled out during maintenance work and
serves as a template for the creation and orderly keeping of an on-going maintenance
book!
9
6
7
8
5
4
10
3
2
1
Item Designation
1
Safety diaphragm
2
Flange
3
O-ring
4
Pressure valve
5
Dosing head
6
Dosing head screws
7
Cover
8
Bleed valve
9
Suction valve
10
Dosing diaphragm
Tab. 25: Dosing head components