Installation and operating instructions: JUDO UNIDOS digital dosing pump systems JUD-KH 6-50 and 6-100 (cold water) / JUD-HH 6-50 and 6-100 (hot water)
All rights reserved.
JUDO Wasseraufbereitung GmbH
© JUDO Wasseraufbereitung GmbH
Postfach 380
D-71351 Winnenden
Translation into foreign languages and reproduction, even in excerpt form, is only permitted with special
approval.
Tel. +49 (0)7195-692-0
Fax +49 (0)7195-692-188
Revision level: 20.04.2017
E-Mail: [email protected]
Internet: www.judo.eu
12
3.3
Technical data
Performance data
JUD-KH/HH
6-50
6-100
Max. dosing capacity
(at max. system-induced back pressure)
[l/h]
6.8
Displaced volume
(at max. system-induced back pressure)
[ml/stroke]
0.81
Adjustment range
[1:X]
1000
Max. stroke frequency
[Strokes/min.]
140
Machine data
Cold/hot water injection point
[“]
½ external thread
Dosing tube (o.d./i.d.)
[mm]
6/4
Max. permissible system-induced back pressure
[bar]
10
Min. required system-induced back pressure *
[bar]
1
Maximum permissible ambient temperature
[°C]
35
Maximum permissible water temperature cold water injection point [°C]
35
Maximum permissible water temperature hot water injection point [°C]
140
Electrical data
Electrical connection (via mains plug)
[VAC]
100-240 ± 10%
Frequency
[Hz]
50/60
Power consumption dosing pump
[W]
19
Power consumption optional electrical stirrer
[W]
30
Max. loading signal inputs
[V/mA]
12/5
Min. contact length
[ms]
5
Max. contact frequency
[Hz]
100
Max. voltage relay output
[VAC/VDC]
30
Max. ohmic loading relay output
[A]
0.5
Degree of protection
IP 65, Nema 4X
Protection class
II
Fill data and weights
Dosing tank volume
[l]
50
100
Net weight approx.
[kg]
8
10
General data
Dosing pump type
6D-10
Max. sound pressure level
[dB(A)]
60
Max. air humidity (non condensing)
[%]
96
Max. height above mean sea level (MSL)
[m]
2000
Tab. 5: Technical data
Data relative to max. back pressure (incl. non-return valve, injection unit), 230VAC/50Hz,
water dosing medium and fully bled dosing head!
* Applies when using original JUDO cold or hot water injection points!