6. APPLICATOR ADJUSTMENT
5.1 Terminal Feed Position Adjustment.
CAUTION
The following adjustments require the removal of the safety guards
and must only be carried out by authorised competent persons.
There is a risk of serious crushing injury in tooling exposed by the
removal of the safety guards. Ensure that fingers are kept away
from the moving parts of the applicator.
When using the MK-L Applicator
Adjust the terminal feed position to adjust the terminal crimping position.
Before making this adjustment be sure that the applicator is mounted in
the crimping machine correctly and the press ram is at Top Dead Centre.
Loosen the 5mm cap head socket screw and the knurled collar using a
small length of silver steel or similar, as indicated on the photograph.
With the aid of the silver steel or a flat-ended screwdriver rotate the
adjustment shaft so that the feed-finger places the terminal in the correct
position for crimping.
Rotate the shaft counter-clockwise to move the terminal forward, and
clock-wise to move it backwards.
When the adjustments are completed, tighten the knurled collar first
followed by the cap screw.
Rotate the press through one revolution manually (see page 10), and
check the resultant crimped terminal. If the appearance of the terminal is
not correct repeat the above adjustment operation and check again.
When a satisfactory result is achieved, replace the
guards, connect the crimping machine to the power
supply and recommence the crimping operation.
When using the MKS-L Applicator
Adjust the terminal feed position to adjust the terminal crimping position.
Before making this adjustment be sure that the applicator is mounted in
the crimping machine correctly and the press ram is at Top Dead Centre.
To position a terminal at the centre of the die, follow the procedure
below.
Loosen the 5mm cap head socket screw and the knurled collar using a
small length of silver steel or similar, as indicated on the photograph.
With the aid of the silver steel or a flat-ended screwdriver rotate the
adjustment shaft so that the feed-finger places the terminal in the correct
position for crimping.
Rotate the shaft counter-clockwise to move the terminal to the right
(forwards), and clock-wise to move it to the left (backwards).
When the adjustments are completed, tighten the knurled collar first
followed by the cap screw.
Rotate the press through one revolution manually (see page 10), and
check the resultant crimped terminal. If the appearance of the terminal is
not correct repeat the above adjustment operation and check again.
When a satisfactory result is achieved, replace the
guards, connect the crimping machine to the power
supply and recommence the crimping operation.
SCREW
COLLAR
Содержание AP-K2