JOHNSON CONTROLS
126
FORM 160.54-O1
historY sCreeN
oVerVieW
This screen allows the user to browse through the faults.
In order to get a more thorough reporting of the system
conditions at the time of the recorded shutdown, move
to the sub-screen
HISTORY DETAILS.
The user may use the
Select Fault
button to select the
history to view. At this point the
View Details
but-
ton is used to jump to a sub-screen containing stored
chiller parameters values at the time of the shutdown.
Additionally, the
Print History
button can be used to
generate a hard-copy report of the parameter values at
the time of the shutdown.
dispLaY oNLY
Last normal Shutdown
This window displays the date and time and the descrip-
tion of the last normal shutdown. A normal shutdown
is defined as:
- Local (Panel rocker switch)
- Remote (Digital, Analog or ISN)
Last Fault While Running
This window displays the date and time and the de-
scription of the last safety or cycling shutdown while
the system was running.
Last Ten Faults
This window displays a chronological listing (most
recent first) of the date and time and the description of
the last ten safety or cycling shutdowns that occur while
the system is running or stopped.
prograMMaBLe
Print History
Access Level Required
: VIEW
This generates a report listing the status of the chiller
parameters at the time of the selected shutdown.
Print All Histories
Access Level Required
: VIEW
This generates a report listing the status of the chiller
parameters at the time of each of the stored shutdowns.
NaVigatioN
Home
Access Level Required
: VIEW
Causes an instant return to the Home Screen.
View Details
Access Level Required
: VIEW
Causes a move to a sub-screen containing the value of
select chiller parameters at the time of the associated
shutdown.
00661VIP
fig. 34
optiView Control Center
Содержание YORK YK MaxE
Страница 10: ...JOHNSON CONTROLS 10 FORM 160 54 O1 OptiView Control Center THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 17: ...FORM 160 54 O1 17 JOHNSON CONTROLS 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 59: ...FORM 160 54 O1 59 JOHNSON CONTROLS 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 65: ...FORM 160 54 O1 65 JOHNSON CONTROLS 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 79: ...FORM 160 54 O1 79 JOHNSON CONTROLS 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 91: ...FORM 160 54 O1 91 JOHNSON CONTROLS 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 105: ...FORM 160 54 O1 105 JOHNSON CONTROLS 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 113: ...FORM 160 54 O1 113 JOHNSON CONTROLS 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 123: ...FORM 160 54 O1 123 JOHNSON CONTROLS 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 133: ...FORM 160 54 O1 133 JOHNSON CONTROLS 2 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 166: ...JOHNSON CONTROLS 166 FORM 160 54 O1 Printers...
Страница 183: ...FORM 160 54 O1 183 JOHNSON CONTROLS...