The Central Supervisory Equipment shall be installed in a temperature controlled
environment. A temperature controlled environment is defined as one that can be
maintained between 14° - 10°C (55° - 95°F) by HVAC system. Twenty-four hours on standby
power shall be provided for the HVAC system. The standby power system for the HVAC
system may be supplied by an engine driven generator alone. A standby battery is not
required to be used.
•
A marking to identify the application and signaling function of the product is located on the
inside of the unit (inner door sticker).
•
For certified commercial proprietary control unit accessory applications, the requirements of
UL 1076, Commercial Proprietary Control Unit Accessory also apply.
•
The reader(s), that is(are) designated to arm or disarm the alarm system, must be within the
secured side of the customer premises.
•
The following Kantech readers have been validated by UL for the UL 1076 Standard:
P225W26, P225KPW26, P225XSF, P225KPXSF, P325W26, P325KPW26, P325XSF, P325KPXSF and
P600.
•
All alarms shall be reported and acknowledged in the following priority:
Note:
To set these priorities, please adjust the Event Parameters, found in EntraPass
System.
- Fire alarm and industrial supervision where a risk of injury to persons, or damage or
destruction of property may be involved.
- Hold-up or panic alarm.
- Burglar alarm.
- Watchman tour (Guard tour).
- Fire-alarm supervision.
- Burglar-alarm supervision.
- Industrial supervision where a risk of injury to persons, or damage or destruction of
property will not be involved.
•
If multiplex system signals are transmitted directly from the protected systems to the
central supervising station and the loss of the channel prevents the receipt of signals from
protective circuits beyond the fault, the number of separate signals on a single channel shall
be limited to 1000.
•
Minimum 4 hours of stand-by power provided by a standby rechargeable battery, rated 12V,
7Ah. Loss of AC signal is transmitted immediately to the central station. Required use of
Reader's LED (flashing) as acknowledgement signal indicator.
•
Use EntraPass and under Definition/Alarm System/Door enable the option "Supervised door
when armed" when using the Reader's flashing LED to indicate the acknowlegdment signal.
POE/POE+ feature is not permitted for UL 1076.
•
The supervision of the IP network connection between a KT-1 and EntraPass is controlled
by the network pulse time. You can program the network pulse time in EntraPass from 15
seconds up to 10 minutes. The default times are 1 minute for EntraPass Corporate Edition
and 15 seconds for EntraPass Global Edition. For UL listed installations, the allowed range
for the network pulse time is from 15 seconds up to 140 seconds. The loss of communication
notification will occur when the network pulse time has elapsed twice plus 15 seconds.
FCC & IC
Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received including interference that
may cause undesired operation.
•
This class B digital apparatus meets all requirements of the Canadian Interference Causing
Equipment Regulations CAN ICES-3 (B) / NMB-3 (B).
CE & RCM
•
EN 60950-1, EN 62368-1, EN 50130-4:2011, EN 61000-6-3. CE Compliance in accordance with
applicable LVD and EMC Directives.
•
Australia/New Zealand: RCM Compliance.
KT-1 One-Door Controller Installation Guide
53
Содержание Tyco KT-1
Страница 1: ...KT 1 One Door Controller Installation Guide D29008966R009 2021 03 08 DN2186 2103 ...
Страница 2: ......
Страница 8: ......
Страница 24: ...Figure 5 KT 1 PCB inputs and outputs 22 KT 1 One Door Controller Installation Guide ...
Страница 26: ...Figure 6 KT 1 controller with KT PS4085 power supply 24 KT 1 One Door Controller Installation Guide ...
Страница 29: ...Figure 8 KT 1 PCB EU inputs and outputs KT 1 One Door Controller Installation Guide 27 ...
Страница 56: ...KT 1 One Door Controller Installation Guide 54 ...