Powering the KT-1-PCB using an external power
supply
•
Connect the external power supply to the 12 VDC input terminals.
Reset options
The controller has four reset options:
•
•
•
•
To reset the controller, see
Soft reset
If you perform a soft reset on a KT-1, the following occurs:
•
If all of the controller's memory definitions and parameters are valid, they are verified and
kept intact. If they are not valid, the controller goes into a hard reset.
•
If it is valid, the internal event buffer is maintained.
•
If it is defined, the previous IP address is kept.
•
You see one of the following messages:
Power ON Soft Reset
,
Manual Pushbutton Soft
Reset
, or
Operator Soft Reset
.
•
The LED pattern does not change during the reset.
Table 10: Soft reset LED pattern
EntraPass edition
Communication status
LED pattern
All editions
Offline
Fast flashes
Global
Online
1 flash every second
Corporate
Online
3 flashes every second
Hard reset
If you perform a hard reset on a KT-1, the following occurs:
•
All of the controller's memory definitions reset to their default values.
•
The internal event buffer clears.
•
If it is valid, the IP address is kept.
•
The LED pattern is in a hard reset state: 4 flashes every second, if it is not in a factory default
or forced default static state.
•
You see the following message:
Controller Hard Reset
.
•
The internal real time clock (RTC) and clock reset to the default time and date values of
January 1 2014, 00:00:00, Wednesday.
Forced default static
If you perform a forced default on a KT-1, the following occurs:
•
If all of the controller's memory definitions and parameters are valid, they are verified and
kept intact. If they are not valid, the controller goes into a hard reset.
•
If it is valid, the internal event buffer is maintained.
•
The IP address resets to the default static IP: 192.168.1.2 Subnet mask: 255.255.255.0.
•
The LED pattern remains in forced default static mode: a flashing beat of 3 reversed flashes,
until the controller resets to another mode.
KT-1 One-Door Controller Installation Guide
45
Содержание Tyco KT-1
Страница 1: ...KT 1 One Door Controller Installation Guide D29008966R009 2021 03 08 DN2186 2103 ...
Страница 2: ......
Страница 8: ......
Страница 24: ...Figure 5 KT 1 PCB inputs and outputs 22 KT 1 One Door Controller Installation Guide ...
Страница 26: ...Figure 6 KT 1 controller with KT PS4085 power supply 24 KT 1 One Door Controller Installation Guide ...
Страница 29: ...Figure 8 KT 1 PCB EU inputs and outputs KT 1 One Door Controller Installation Guide 27 ...
Страница 56: ...KT 1 One Door Controller Installation Guide 54 ...