Callout
Description
A
Entry reader
B
Extra outputs used as a general annunciator.
C
KT-PS4085 power supply (optional North American model). 12 VDC, 1.5 A.
D
RS485 main network to other KT-1 controllers or the Gateway using a USB-485
interface.
E
Transformer: 16 VAC, 40 VA.
F
120 Volts, 80 Hertz. Class 2 power limited adapter model PTC1640UG. Input
ratings: 12 VAC/620 Hz/40 VA.
Note:
Do not connect to a receptacle controlled by a switch.
G
Battery: 12 V/7 A/H
H
Relay 1: 30 VDC/VAC, 3 Amps Form C
I
Relay 2: 30 VDC/VAC, 3 Amps Form C
J
Door contact
K
Optional end of line resistors
L
Request to exit device
M
Individually programmable zone termination: NC, NO, NEOL, single or double EOL
termination.
N
Tighten the nut to break the paint and ensure there is a secure connection to the
cabinet.
O
RJ12 RS232C port integration
P
RJ45 Ethernet network optional PoE or PoE+ powered.
Q
Connect a 1000 Ohm resistor between the LK- and +12 V if you are not using a
locking device.
R
Door locking device: 12 VDC, 750 mA maximum.
S
Optional exit reader
KT-1 One-Door Controller Installation Guide
23
Содержание Tyco KT-1
Страница 1: ...KT 1 One Door Controller Installation Guide D29008966R009 2021 03 08 DN2186 2103 ...
Страница 2: ......
Страница 8: ......
Страница 24: ...Figure 5 KT 1 PCB inputs and outputs 22 KT 1 One Door Controller Installation Guide ...
Страница 26: ...Figure 6 KT 1 controller with KT PS4085 power supply 24 KT 1 One Door Controller Installation Guide ...
Страница 29: ...Figure 8 KT 1 PCB EU inputs and outputs KT 1 One Door Controller Installation Guide 27 ...
Страница 56: ...KT 1 One Door Controller Installation Guide 54 ...