Figure 18: Connecting card readers
Connecting relay controlled outputs
The following table lists the KT-1 controller's relay controlled output ratings.
Table 9: Relay controlled outputs
Controller
Outputs
Rating
KT-1
RELAY1 and RELAY2
Open-collector, up to 100 mA each
KT-1-PCB
Form C RELAY1 and RELAY2
3 Amps, 30 VAC/VDC, 0.6 power factor
Figure 19: KT-1 relay controlled outputs
Callout
Description
A
Relay outputs: Open collector, switch to ground, 12 VDC 100 mA maximum.
B
12 VDC relays
KT-1 One-Door Controller Installation Guide