Callout
Description
A
Entry card reader
B
RJ45 Ethernet network. Optional PoE or PoE+ powered.
C
Door locking device: 12 VDC, 750 mA maximum.
D
Connect a 1000 Ohm resistor between LK- and +12 V if you are not using a locking
device.
E
Optional end of line resistor.
F
Door contact
G
Request to exit device
H
Individually programmable zone termination: NC, NO, NEOL, single or double EOL
termination.
I
Connect the RS-485 main network to other KT-1 controllers or to the gateway
using a USB-485 interface.
J
Tighten the nut to break the paint and ensure that there is a secure connection to
the cabinet.
K
Battery: 12 V, 7 A/H
L
Connect the ACT (AC trouble) output from the KT-PS4085 to one input on the KT-2
to transmit AC loss events to the monitoring console.
M
Class 2 power limited adaptor model PTC1640UG. Input ratings: 120 VAC / 60 Hz /
40 VA.
Note:
Do not connect to a receptacle that is controlled by a switch.
N
Transformer 16 VAC / 40 VA
O
Optional power supply: KT-PS4085 12 VDC/1.5 A (North American model)
To power the KT-1, use a PoE or PoE+ power source connected to a RJ45 socket, or
a UL listed external supply connected to a terminal block +/- rated 12 VDC / 1.5 A.
P
Extra outputs used as a general annunciator
Q
Optional exit reader
R
Relay outputs: open collector, switch to ground, 12 VDC, 100 mA maximum.
KT-1 One-Door Controller Installation Guide
21
Содержание Tyco KT-1
Страница 1: ...KT 1 One Door Controller Installation Guide D29008966R009 2021 03 08 DN2186 2103 ...
Страница 2: ......
Страница 8: ......
Страница 24: ...Figure 5 KT 1 PCB inputs and outputs 22 KT 1 One Door Controller Installation Guide ...
Страница 26: ...Figure 6 KT 1 controller with KT PS4085 power supply 24 KT 1 One Door Controller Installation Guide ...
Страница 29: ...Figure 8 KT 1 PCB EU inputs and outputs KT 1 One Door Controller Installation Guide 27 ...
Страница 56: ...KT 1 One Door Controller Installation Guide 54 ...