The Test Functions Menu
The Manual mode is no longer implemented. Instead, a new expanded set of test
functions are available from the
Test–Functions Menu
. To test the selected
component, press the
Change Value/Item
key. To change the fuel pump or glow plug
voltage when testing, while pressing the
Change Value/Item
key, press the
◄
- or
►
+
key. The following functions are available ->
Value
Explanation
Pump TestVolt
Opens fuel valve and runs the pump.
Default = 0.500 volts.
Note:
Can be used to prime the pump and fuel system. Make sure
the fuel line is disconnected from the turbine.
GlowPlug Power
Test and / or change glow plug voltage.
Default = 2.100 volts.
GasValve Test
Test starting gas valve.
FuelValve Test
Test fuel valve.
Temp
AD
Temperature value and offset.
Analog Converter value and offset
The LIMITs Menu
The LIMITs menu allows the operator to adjust the following parameters of the turbine,
within the allowable values, according to the performance requirements of a particular
model.
Value
Explanation
Minimum RPM
Turbine idle speed
Maximum RPM
Turbine maximum speed
LowBat Warning
Battery warning function, Enabled/Disabled
Default = Disabled (OFF)
GlowPlug Power
Glow plug voltage, The glow plug will glow with the selected
voltage when the
Change Value/Item
key is pressed.
Default = 2.100V
Gas Flow
Sets the amount of starting gas that will flow when the turbine is
started. The range is from 10 to 100% adjustable in 10%
increments.
49
Содержание SPH5
Страница 60: ...Copyright JetCat USA LLC 2001 2007 60 ...