Explanation for Turbine Shut Down
In the run menu, state selection, are the following explanations for the last shut down
condition of the turbine.
Code Value
Explanation
1 R/C
Off
Throttle stick and throttle trim moved to the minimum position.
2 OverTemp
Turbine running over temperature. Exceeded high
temperature parameter and time out.
3 IgnTimOut
Turbine did not ignite within programmed time interval.
4 AccTimOut
Turbine achieved ignition, but did not accelerate within
programmed time interval.
5 Acc.Slow
Turbine achieved ignition, but acceleration was less than the
programmed value, during startup.
6 Over-RPM
Turbine exceeded the maximum RPM, by 5% and a delay of
0.5 seconds.
7 Low-RPM
Turbine running under the minimum RPM, by 10% and a
delay of 3 seconds. Usually triggered by a flame out.
8 BattryLow
Battery pack is dead. Cell voltage is < 1.0V.
9
10 LowTemp
EGT dropped below the minimum value. A dislodged EGT
sensor can trigger this shut down.
11 HiTempOff
EGT exceeded the maximum range (~950 °C).
12 GlowPlug!
Defective glow plug.
13 WatchDog
ECU processor was locked out usually from static discharge
or voltage spike in power supply.
14 FailSafe
Turbine was shut down from a failsafe timeout condition.
15 ManualOff
Turbine was shut off by using the GSU.
16 PowerFail
The power failed to the ECU when the turbine was running.
This will occur if the power was lost because of a defective
battery, connection or if the switch is turned off before the
engine is shut-down.
Note: If this state is displayed the Info, Min/Max and
Statistics menus retain information from the previous
run.
17 TempSensor
Fail
EGT sensor failed.
Note: This could happen only during startup.
43
Содержание SPH5
Страница 60: ...Copyright JetCat USA LLC 2001 2007 60 ...