User Manual ECOSTEP®54
34
Subject to change without notice!
In the Profi le Velocity Mode the following parameters can be confi gured:
Fig. 7.10: Parameters in the Profile Velocity Mode (F6)
Th e parameters are described in the following table.
Table 7.7: Parameters in the Profile Velocity Mode for ECOSTEP54
Parameter
Description
target_velocity
Target velocity in the operation modes 3, -3 and -4 [inc/s]
velocity demand_val Demanded velocity at the moment [inc/s]
velocity actual_val
Actual velocity value [inc/s]
For PLC programming in positioning mode and velocity mode please refer to the fl owcharts in the Annex
(Chap. 9.1).
Commissioning of the ECOSTEP®54 is now fi nished. Further confi gurable parameters (e.g. communica-
tion via CANopen) and sequence programming are described in detail in the manual „Objektverzeichnis
ECOSTEP® und ECOVARIO®“.