User Manual ECOSTEP®54
30
Subject to change without notice!
9. Confi gure holding brake
If the holding brake shall be connected alternatively to connector X5 OUT5 ... 8, the mapping of the respec-
tive output has to be set to 0x21240020. AndMask and CmpMask specify the respective output. Th e settings
are done in the menu „Device Confi guration -> Digital Output Confi guration“.
Fig. 7.4: Configuring the holding brake in the window „Digital Output Configuration“ (F8)
10. Switch on power supply
11. Switch on DC link circuit
0,5 s aft er switching on the power supply the DC link circuit relay can be switched on. Th erefore, a voltage
of + 24V has to be applied across pins REL+ and REL - of connector X11.
12. Set „Switch On“ bit in the control word
Th e drive is switched on by soft ware.
Menu „Separate Axis DS402 -> Device Profi le DS402 - Ax -> Device State Control“:
Fig. 7.5: Control word and status word in the „Device State Control“ window
ECOSTEP54 is controlled via the control word and the status word. In this menu, the bits of both are dis-
played for each axis separately and the control word can be modifi ed.
13. Set „Enable Operation“ bit in the control word
Th e drive is ready now for further commands. Th e drive can be switched off any time by resetting the „En-
able Operation“ bit.