P/N 960-100175R_Rev. 4 {EDP #200824}
© 2013, Japan CashMachine Co., Limited
6 - 7
Calibration and Testing
Taiko™ Series Banknote Acceptor
Section 6
Calibration Procedures
Calibration Description
Calibration sets a starting reference point for all
Optical and Magnetic Sensors within the Taiko™
Unit.
Calibration Tool Requirements
The following equipment and tools are required to
perform Taiko™ Workbench calibration:
•
JCM Taiko™ Banknote Acceptor (PUB-7 or
PUB-11)
•
JCM External Power Supply (EDP# 116125,
JAC# 501-000187RA) or equivalent
•
KS-070 Reference Paper (EDP# 1199581,
JAC# 501-000200RA)
•
KS-088 Reference Paper (EDP#, JAC# 501-
100256R).
When to Calibrate
–
After new software has been downloaded
–
After a Banknote Acceptor component has
been disassembled/reassembled for repair
–
After the CPU and/or Sensor Circuit Board
has been replaced.
Initial Settings
1. Make sure power is not supplied to the Taiko™
Unit intended for calibration, and remove it from
its Bezel mounting (See Figure 6-11).
2. Connect
an
External Power Supply per the Figure
6-1 illustration.
3. Set Right Side Panel DIP Switches No. 1, 2 and 8
ON
(See Figure 6-12), and apply AC power to the
External DC Power Supply Unit.
4. Confirm that the Front Panel LED is flashing a
White Light.
5. Set DIP Switch No.1 to ‘
OFF
’ and confirm that
the
Green
Front Panel LED is lit (ON).
6. Insert the KS-070 Reference Paper into the
Taiko™ Unit (See Figure 6-13
a
). If calibration
of the Barcode Coupon Specification Unit is also
required, insert the KS-088 Reference Paper.
When the Rollers begin to rotate, continue insert-
ing the Reference Paper all the way into the Unit
b
).
7. When the Reference Paper reaches the inner
limit, the Front Panel LED will flash a
Green
Color.
8. Turn DIP Switch No.8 ‘
OFF
’ to begin the Cali-
bration Procedure.
9. Confirm that the Front Panel
Yellow
LED is lit,
indicating a Sensor Adjustment is occurring.
10. When the Paper adjustment is complete, the
Reference Paper will exit out of the Taiko™ Unit
automatically (See Figure 6-14).
11. Remove the KS-070 or KS-088 Reference Paper.
The Front Panel LED will flash
Green
.
12. Turn DIP Switch No.8 ‘
ON
’ to begin the Non-
Paper Calibration Procedure.
13. When the Non-Paper Adjustment and EEPROM
data writing procedures are complete, confirm
that the Front Panel LED is lit a
Blue
Color.
Performance Test Diagnostics
The Taiko™ Unit is equipped with various diag-
nostic features to aid in repair and maintenance.
This portion describes the test procedure required
for each function using specific DIP Switch set-
tings to identify the cause of a suspect failure con-
dition.
NOTE: This task should only be
accomplished at a Workbench.
Figure 6-11
Removing Taiko from Bezel Mount
Figure 6-12
Adjustment DIP Switch Setting
ON
Figure 6-13
Reference Paper Insertion
a
b
KS-070 or KS-088
Figure 6-14
Adjustment Complete Paper Ejection
WARNING: If the adjustments and/or
EEPROM Data writing procedures are
not successfully completed, the
Red
LED will light! In this case, start the
procedure over again from the very
beginning.