C20
MAINTENANCE
9803/1250
C20
Issue 1
FAULT FINDING
*The remedy in certain should be carried out by your JCB Dealer.
Symptom
Possible Fault
Remedy
Breaker fails to operate.
No flow from supply.
*Check output with flow and
pressure tester.
Hoses incorrectly fitted.
Check that pressure feed is
connected to top port on the breaker.
Insufficient movement of
*The trigger spool should move
trigger spool.
approx. 5 mm (0.2 in). Check lever
mechanism.
Main spool jammed or
*Remove and check.
damaged.
Clean all associated parts.
Striker piston seized.
*Remove and check for ‘pick-up’ on
piston feeder or barrel.
Replace any damaged parts.
Breaker lacks breaking power.
Insufficient available pressure.
*Check Main Relief Valve - for
settings refer to
Specification
section.
Low accumulator gas pressure
*Re-charge the accumulator as
(Normally associated with
detailed in this section.
violent shaking of hoses).
Hexagon bush in nose casting
Apply JCB Retainer ( High Strength )
loose.
and press back.
Breaker runs slow.
Insufficient flow.
*Check the flow rate - for settings
refer to
Specification
section.
Cold oil
Warm up the oil supply. Optimum
temperature 20 - 70ºC (68 - 158 ºF).
High return line back pressure.
*Check return line back-pressure.
Pressure should not exceed 12 bar
(174 lbf/in
2
).
Incorrect oil.
Use only JCB Special Hydraulic Oil
(part no. 4002/0224).
Breaker runs hot.
Inadequate cooling of hydraulic
Check oil supply has adequate
oil.
cooling. Temperature should not
exceed 80 ºC (176 ºF).