B12
MAINTENANCE
9803/1250
B12
Issue 1
OPERATOR FAULT FINDING
Specifications
*The remedy in certain cases should be carried out by your JCB dealer
Symptom
Possible Fault
Remedy
Breaker fails to operate.
No flow from supply.
*Check output with flow and pressure tester.
Hoses incorrectly fitted.
Check that pressure feed is connected to
top port on the breaker.
Insufficient movement of
*The trigger spool should move approx.
trigger spool.
5mm (0.2in.). Check lever mechanism.
Main spool jammed or
*Remove and check.
damaged.
Clean all associated parts.
Striker piston seized.
*Remove and check for 'pick-up' on piston feeder or
barrel. Replace any damaged parts.
Breaker lacks breaking power.
Insufficient available
*Check Main Relief Valve -
pressure.
minimum setting 76 bar (1100 lbf/in
2
) for the 22 kg
Breaker and 110 bar (1595 lbf/in
2
) for the 25 and
29 kg Breaker.
Low accumulator gas pressure
*Re-charge the accumulator
(Normally associated with
violent shaking of hoses).
Hexagon bush in nose
Apply JCB Retainer( High Strength ) and press back.
casting loose.
Breaker runs slow
Insufficient flow.
*Check that the flow rate is between
18 - 22 l/min. (3.96 - 4.84 gal/min.).
Note:
For HM29 (30 litre.) flow rate 28 - 32l/min
(6.16 - 7.04 gal/min).
Cold oil.
Warm up the oil supply. Optimum
temperature 20 - 70C (68 - 158F).
High return line back pressure.
*Check return line back-pressure.
Pressure should not exceed
12 bar (174 lbf/in
2
).
Incorrect oil.
Use only JCB Hydraulic Oil HP32
(part no. 4002/1000).
Breaker runs hot.
Inadequate cooling of
Check oil supply has adequate cooling.
hydraulic oil.
Temperature should not exceed
80C (176F).
Noise Level Standard:
Noise Level EC Directive 84/537/EEC (Lwa)
Vibration Standard:
Vibration Weighted RMS Acceleration ISO 8662 Part 5 (m/s
2
)
Min.
Acc.
EHTMA
Pressure
Relief Valve
Gas
Model
Length
Weight
Steel Size mm (in)
Noise Level
Vibration
Category Flow Rate
Range
Settings
Pressure
929/92400 760 mm
25 kg
32 x 160 (11/4 x 61/4)
109 Lwa
4.0 m/s 2
C
18-22 L/Min 90-110 bar
110 bar
43 bar
929/92500 720 mm
22 kg
22 x 82.5 (7/8 x 31/4)
106 Lwa
3.4 m/s 2
C
18-22 L/Min 69-86 bar
76 bar
38 bar
929/92600 680 mm
22 kg
25 x 108 (1 x 41/4)
106 Lwa
3.4 m/s 2
C
18-22 L/Min 69-86 bar
76 bar
38 bar
929/92700 730 mm
29 kg
32 x 160 (11/4 x 61/4)
108 Lwa
5.0 m/s 2
C
18-22 L/Min 90-110 bar
110 bar
50 bar
929/92900 730 mm
29 kg
32 x 160 (11/4 x 61/4)
110 Lwa
5.9 m/s 2
D
28-32 L/Min 90-110 bar
110 bar
50 bar