CHARGING THE ACCUMULATOR - HM 22, 25, 29
X3
743310
!
WARNING
Use only nitrogen gas to charge the accumulators. The
use of any other gas can cause the accumulators to
explode. Remember that although nitrogen is not
poisonous, you can be killed by suffocation if it displaces
air in your workplace. Do not allow excessive quantities
of nitrogen to be discharged into the atmosphere.
This procedure must not be carried out with the breaker
(or pick) connected to a source of hydraulic supply.
During charging, the breaker must be securely mounted
in the upright position. This prevents the breaker falling
over whilst charging, thereby preventing uncontrolled
escape of gas.
EQUIPMENT REQUIRED.
a
Nitrogen bottle
Minimum residual pressure 70 bar (1000lbf/in
2
)
b
Regulator (with contents and outlet gauge)
Outlet pressure should be controllable up to 55 bar
(800 lbf/in
2
)
c
Charging adaptor (JCB part no. 929/05800)
together with 3/8 in. BSP Dowty washer.
d
Connecting hose
Suitable hose of minimum operating pressure 207 bar
(3000 lbf/in
2
)
, together with female coupling (JCB part
no.929/06303).
CHARGING PRESSURE
The charging pressure should not exceed 50 bar (800
lbf/in
2
)
.
Refer to Specification section for specific
accumulator pressures.
CHARGING PROCEDURE
1
Remove the slotted cover screw
1
from the breaker.
2
Using a 4 mm. Allen key
2
,
slowly
loosen the charging
screw approximately 3 turns.
Do not
remove the screw.
3
Fit the 3/8 in. Dowty washer
5
to the charging adaptor
3
and screw into the breaker.
Do not
overtighten, hand
tight is adequate.
4
Ensure that the nitrogen bottle outlet pressure is at zero
and then connect the charging hose
4
to the charging
adaptor
3
.
5
Gradually increase the nitrogen bottle outlet pressure
until the required level is reached (see
Specification
section).
6
Push in knob
6
on the charging adaptor
3
to engage the
charging screw and tighten.
Do not
overtighten.
7
Shut the regulator valve on the nitrogen bottle and using
the venting screw
7
, release the trapped gas in the
hose.
8
Disconnect the charging hose
4
and unscrew the
charging adaptor
3
from the body of the breaker.
9
Finally, tighten the charging screw using a 4mm. Allen
key
2
and refit the cover screw
1
after applying Loctite
270 to the threads.