![jcb 929/05400 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/jcb/929-05400/929-05400_service-manual_640105024.webp)
C2
MAINTENANCE
9803/1250
C2
Issue 1
BREAKER DISMANTLING - STANDARD AND VIBRO-DAMPED (cont’d)
6
Unscrew and remove check valve
E
ensuring that
the breaker is positioned as shown above so as to
avoid losing the check valve ball
F
.
8
Remove the housing cap
G
and the spool
H
from
the head
J
.
10 For standard handle breakers only
, Using a
press, remove roll pins
N
from the top cover and
remove the trigger. Withdraw the trigger pin
O
.
7
Remove the seals from the lower section of the
barrel casting. A slide hammer will be necessary
to remove the seal housing.
9
Remove the plug
K
, seal washer
L
, spring and
trigger spool
M
from the head.
11 For standard handle breakers only
, remove the
capscrew from inside each handle and remove
the handles from the top cover.