E4
SPECIFICATIONS
9803/1250
E4
Issue 1
HYDRAULIC POWERPACKS
Engines
The
BEAVER III
may be fitted with a
Honda GX240
petrol engine. These engines are fitted with an Oil Alert
system which is designed to prevent engine damage
caused by an insufficient amount of oil in the crank
case. The oil alert system will shut down the engine
before the oil in the crankcase can fall below a safe
limit.
If the Oil Alert system has shut down the engine then
Oil Alert indicator will flash when you attempt to restart
the engine.
If the
Lombardini 15LD315
is fitted it will either be a
Recoil Start Model or an Electric Start Model.
Recoil Start Model:
Pull the starter grip lightly until
resistance is felt, then pull briskly. Do not allow the
starter grip to snap back against the engine. Return it
gently to prevent damage.
Electric Start Model:
Do not use the electric starter
for more than 5 seconds at a time. If the engine fails to
start, release the key and wait 10 seconds before
operating the starter again.
After starting, allow the engine to idle for a few
minutes, then slacken the engine speed control.
Temperature Idling Time
The following times are recommended for allowing the
engine to idle when the temperatures are as indicated.
below -20 °C (-4 °F)
5 minutes
-20 °C to -10 °C (-4 °F to 14 °F)
2 minutes
-10 °C to 5 °C (14 °F to 41 °F)
1 minute
above 5 °C (above41 °F)
20 seconds