C12
MAINTENANCE
9803/1250
C12
Issue 1
BREAKER DISMANTLING - ‘D’ and ‘T’ PICKS (cont’d)
!
!
WARNING
Accumulator
The breaker incorporates a pressure accumulator.
This accumulator is pressurised even when there is
no hydraulic pressure to the breaker. Attempting to
dismantle the accumulator without first releasing
the pressure can cause injury or death. Gas
pressure must be released before carrying out
further dismantling.
Note:
Once gas has been released, a special charging
tool (part no. 929/05800) is required to re-charge the
accumulator. Re-charging the accumulator must only
be undertaken by a suitable qualified person.
13 Releasing Gas Pressure from the accumulator.
Remove the cover screw
37
to gain access to the
charging screw
38
. Insert a 4 mm allen key and
slowly loosen the charging screw approximately 3
or 4 turns listening for all the gas to escape.
Tighten the charging screw approximately 3 or 4
turns. Refit the cover screw.
15
Hold the barrel/nose assembly above the
workbench with the check valve housing pointing
downwards. Remove the check valve
43
with the
check valve ball 4
4
.
12
Remove plug
33
, seal
34
, spring
35
and trigger
spool
36
.
14 Dismantling the Accumulator Assembly (see
WARNING)
. Remove the four capscrews
39
and
separate the accumulator top
40
from the
accumulator head
41
. Remove the diaphragm
42
from the head.
16
Using a suitable drift, push out the piston
45
and
piston feeder
46
from the barrel
49
. Separate the
piston from the feeder. Remove and discard ‘O’
ring
47
.
Содержание 929/05400