BREAKER DISMANTLING - STANDARD AND VIBRO-DAMPED (cont’d)
17
Loosen the charging screw
U
slowly
approximately 3 or 4 turns, listening for all the gas
to escape. Refit the cover screw
T
.
19 For standard handle breakers only
, remove the
four capscrews and remove the cover from the
head.
21 For vibro-damped handle breakers only
,
withdraw the trigger pin
O
. Remove the four
capscrews and remove the handle bracket from
the head.
18 For standard handle breakers only
, when you
are sure that all the gas in the accumulator has
been evacuated, remove the safety screw
V
from
the head.
20 For vibro-damped handle breakers only
,when
you are sure that all the gas in the accumulator
has been evacuated, remove the safety screw
V
from the head.
22
Remove the diaphragm
X
and ‘O’ ring seal
Y
from
the head.