© JBG-HT (v.2.0)
5
INSTRUCTION MANUAL
– HEAT PUMP
1. CHARACTERISTICS
MONOBLOCK HEAT PUMP
ZHHS-01-10K-R290-V5-M / ZHHS-01-15K-R290-V5-M
Performance data – heating (EN 14511)
ZHHS-01-10K-R290-V5-M ZHHS-01-15K-R290-V5-M
A7/W35
Power range (min-max)
1
kW
3,38 ÷ 9,86
5,35 ÷ 14,7
Partial load
1
kW
6,60
8,70
Power consumption
1
kW
1,45
1,64
COP
1
4,56
5,29
A7/W45
Power range (min-max)
2
kW
3,00 ÷ 8,89
5,22 ÷ 14,81
Partial load
2
kW
5,29
8,58
Power consumption
2
kW
1,44
2,15
COP
2
3,67
3,99
A7/W55
Power range (min-max)
3
kW
2,88 ÷ 8,51
4,92 ÷ 13,76
Partial load
3
kW
5,50
9,20
Power consumption
3
kW
2,00
2,89
COP
3
2,75
3,19
A2/W35
Power range (min-max)
4
kW
3,00 ÷ 9,01
4,67 ÷ 13,65
Partial load
4
kW
3,00
4,67
Power consumption
4
kW
0,67
0,98
COP
4
4,48
4,75
A-7/W35
Maximum power
5
kW
6,80
11,17
Power consumption
5
kW
2,47
4,08
COP
5
2,75
2,73
Cooling data
Pump type
air / water
Refrigerant type
R290
Refrigerant amount
kg
0,55
0,8
Maximum working pressure
bar
26
Compressor type
inwerter scroll
Oil
PAG PZ46M
Adjustment type
electronic
H DHW
Minimum working pressure
bar
1,0
Maximum working pressure
bar
3,0
Rated flow
m³/h
1,17
1,48
External operating temperature range
°C
from -20 to +35
Feed water temperature
°C
from +20 to +65
Physical dimensions
Depth x width x height
mm
535 x 1155 x 935
535 x 1155 x 1530
Weight
kg
132
166
Water connections
G 5/4 "
Sound power level
dB
59
61
Air flow
m³/h
3500
6000
Electrical data
Electrical connection
V/Ph/Hz
400 / 3~ / 50
Protection rating
IP24
Electric heater power
(with the option of hydrobox / hydrotower)
kW
3 / 6 / 9
Maximum starting current
A
10
13
Fan power consumption
W
50
100
Number of fans
1
2
Fan rotor speed
RPM
700
SCOP
W35
4,46
/
W55
3,31
W35
4,45
/
W55
3,34
Energy efficiency class
Device with a regulator – feed temperature 35°C / 55°C
W35
A+++
/
W55
A++
Heating temperature:
water I/O temperature: 30°C / 35°C,
Ambient temperature: DB 7°C / WB 6°C;
Heating temperature:
water I/O temperature: 40°C / 45°C,
Ambient temperature: DB 7°C / WB 6°C;
Heating temperature:
water I/O temperature: 50°C / 55°C,
Ambient temperature: DB 7°C / WB 6°C;
Heating temperature:
water I/O temperature: 30°C / 35°C,
Ambient temperature: DB 2°C / WB 1°C;
Heating temperature:
water I/O temperature: 30°C / 35°C,
Ambient temperature: DB -7°C / WB -8°C;