INSTRUCTION MANUAL
– HEAT PUMP
4.9.3.
Diagram of the refrigeration system
PT
PT
PT
A
B
C
D
E
F
1
2
3
4
5
6
7
8
A
B
C
D
E
F
1
2
3
4
5
6
7
8
1
Sprężarka scroll
2
Falownik
3
Czujnik temperatury
4
Presostat miniaturowy
5
Przetwornik ciśnienia HP
6
Zaworek serwisowy
7
Zawór czterodrogowy z cewką
8
Skraplacz
9
Filtr odwadniacz
10
Zawór EEV
11
Parownik
12
Wentylator
13
Filtr siatkowy
14
Przetwornik ciśnienia LP
15
Pompa cyrkulacyjna
16
Przetwornik przepływu
17
Odpowietrznik automatyczny
18
Grzałka opaskowa karteru
19
Grzałka ociekowa tacy
D
S
C
E
1
3
4
5
6
7
8
9
10
13
12
6
3
14
2
15
16
17
11
3
3
3
3
18
19
1
Scroll compressor
2
Iverter
3
Temperature sensor
4
Miniature pressure switch
5
HP pressure transmitter
6
Maintenance valve
7
4-way valve with coil
8
Condenser
9
Dehydration filter
10
EEV valve
11
Evaporator
12
Fan
13
Mesh filter
14
LP pressure transmitter
15
Circulation pump
16
Flow sensor
17
Automatic vent
18
Crankcase band heater
19
Tray drip heater
Fig. 35. Refrigeration system diagram
4.9.4.
Water supply system
Before filling or any subsequent refilling of the system, make sure to check the quality of the water in the heating
system:
•
Visually check the water for precipitation of other materials. If this occurs, the user is required
to clean the system.
•
Use only demineralized heating water or water that complies with the VDI 2035 standard. Fail-
ure to do so may result in a decrease in the efficiency of the device and even damage to its
components.
Desliming of the system is not included in the installation and commissioning of the heat pump.
•
Check with a magnetic rod whether magnetite (iron oxide) is present in the water. If found, treat
the water accordingly.
In the case of an existing installation, clean the system and install a magnetic filter.
•
Check the pH value of the water at a temperature of 25°C.
It is generally accepted that water should be treated if the values in Table 16 are not met.
Heating
power
Water hardness in relation to the volume of the installation
kW
°dH
mol/m
3
°dH
mol/m
3
°dH
mol/m
3
< 50
< 16,8
< 3
11,2
2
0,11
0,02
Tab. 16. Recommended water hardness values
Improper additives can cause the risk of material damage and harmful physical changes in parts. This can be
especially true for seals of all kinds. For this reason, antifreeze, corrosion inhibitors and sealants should not be
used. The technical parameters of the installation water should be checked at the annual technical inspection of
the heat pump and corrected as necessary to the required values.