4-47
4.10 System Settings
Select "SYSTEM" on the main menu to display the system setting screen.
To change the system settings, place the unit in maintenance mode.
An overview of each submenu is as follows.
(1) UNIT:
The unit of speed and heigtt is set.
(2) TIME DIFF: Set the time difference between UTC and local time.
(3) DATE DIFF: Select the date format.
(4) MAG DORR: Automatic or manual magnetic correction or turn magnetic correction off can be
selected.
(5) LORAN C:
Convert latitude and longitude to LORAN C
(6) DATUM:
A geodetic system can be selected from the list in "Appendix 1 Geodetic
System."
4.10.1 Setting Speed and Anntena height Unit
You can select "NM," "kn," "km," "km/h," "mi," "mi/h," "m," and "m/s" for speed and "m", "ft" and "fm" for
anntena height unit.
1. Refer to "4.15.1 Change to a maintenance mode" and display the maintenance menu.
2. Press
the
key to select "SYSTEM", "UNIT" and "DIST/SPD" or "ANT HEIGHT" in order.
3. Press
the
key to select the unit, and press the
key.
4.10.2 Setting the Time Difference
You can set the time difference between your current location and UTC.
For Japan, the time difference is +9 hours, so you would enter +09:00.
When a time difference is set, “L” is displayed on the upper right of the screen.
1. Refer to "4.15.1 Change to a maintenance mode" and display the maintenance menu.
2. Press
the
key to select "SYSTEM" and "TIME DIFF" in order.
3. Press
the
key to enter the time difference, and press the
key.
Procedure
Procedure
Содержание JLR-7600
Страница 2: ......
Страница 11: ...ix...
Страница 16: ......
Страница 20: ...1 4 1 4 Construction NWZ 4610 Display Unit Unit mm Mass Approximately 0 8 kg NWZ 4610 Desktop type...
Страница 23: ...1 7 NBD 577C Power Supply Outline Drawing Unit mm Mass Approximately 5 4 kg...
Страница 27: ...1 11 NQA 4351 Output Buffer Outline Drawing Unit mm Mass Approximately 0 8 kg...
Страница 29: ...1 13 NCZ 1663 Select Switch Unit mm Mass Approximately 0 2 kg...
Страница 30: ...1 14 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg...
Страница 31: ...1 15 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg...
Страница 32: ...1 16 CQD 10 Junction Box Outline Drawing Unit mm Mass Approximately 1 1 kg 4 7 5 Installation Screw M6...
Страница 33: ...1 17 NKG 94 Printer Outline Drawing Unit mm Mass 2 2 kg or less Printer Rack...
Страница 38: ...2 4...
Страница 42: ...3 4...
Страница 138: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more...
Страница 158: ...6 30...
Страница 160: ...7 2...
Страница 162: ...8 2...
Страница 181: ......
Страница 182: ......
Страница 183: ......