4-69
When the "SEND" or "RECEIVE" of data IN/OUT1 or data IN/OUT2 is set and one port is set,
the other port is also set concurrently. The message that is shown below is displayed to
prevent the unintentional setting of the other port. When setting a port, select “YES”. If “NO” is
selected, the port is not set.
4.15.5.2 Setting
reception
In the reception setting, set a baud rate.
A JRC format cannot be selected as the format.
There is no need to set a sentence or a cycle.
1. Refer to "4.15.1 Change to a maintenance mode" and display a maintenance menu.
2. Select “INTERFACE” and “DATA I/O” in this order by using
.
3. Select a port and an output format that are to be set by using
.
4. Select “RECEIVE” from “DATA IN/OUT” by using
.
5. Return control to the BIT RATE selection screen and select BIT RATE by using
.
Available bit rates are “4800”, “9600”, “19200”, and “38400”.
4.15.6 Setting Contact Input
A contact input port can be set to the following input.
1) DIMMER: Use this option when connecting an external dimmer unit.
2) ACK:
ACK is input from an external unit.
To use an external dimmer unit, the dimmer unit must be set to “EXT DIMMER”. Refer to "4.15.3
Selecting a dimmer unit” for the setting method.
1. Refer to "4.15.1 Change to a maintenance mode" and display a maintenance menu.
2. Select “INTERFACE”, “DATA I/O” and “CONTACT INPUT” in this order by using
.
3. Select an item to be input by using
and press
.
Setting port
Select an output format
Select RECEIVE
Select BIT RATE
Supplement
Procedure
Procedure
Содержание JLR-7600
Страница 2: ......
Страница 11: ...ix...
Страница 16: ......
Страница 20: ...1 4 1 4 Construction NWZ 4610 Display Unit Unit mm Mass Approximately 0 8 kg NWZ 4610 Desktop type...
Страница 23: ...1 7 NBD 577C Power Supply Outline Drawing Unit mm Mass Approximately 5 4 kg...
Страница 27: ...1 11 NQA 4351 Output Buffer Outline Drawing Unit mm Mass Approximately 0 8 kg...
Страница 29: ...1 13 NCZ 1663 Select Switch Unit mm Mass Approximately 0 2 kg...
Страница 30: ...1 14 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg...
Страница 31: ...1 15 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg...
Страница 32: ...1 16 CQD 10 Junction Box Outline Drawing Unit mm Mass Approximately 1 1 kg 4 7 5 Installation Screw M6...
Страница 33: ...1 17 NKG 94 Printer Outline Drawing Unit mm Mass 2 2 kg or less Printer Rack...
Страница 38: ...2 4...
Страница 42: ...3 4...
Страница 138: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more...
Страница 158: ...6 30...
Страница 160: ...7 2...
Страница 162: ...8 2...
Страница 181: ......
Страница 182: ......
Страница 183: ......