4-33
smoothed.
It is recommended to set this value only if the calculation result varies largely.
(4) ROUTE
You can set whether to start or stop navigation.
START: Navigation
is
started.
END: Navigation
is
stopped.
(1) To set waypoint update method
Select "LEG CHANGE"
,
select the waypoint update method, and press the
key.
(2) To set direction
Select "DIRECTION"
,
select the direction, and press the
key.
(3) To set smoothing of ship speed
Select "SPEED SMOOTHING," "ON", enter the value, and press the
key.
4. Select
"ROUTE"
,
select "START," and press the
key.
To stop the navigation, select "END" and press the
key.
4.6.2 Selecting a Waypoint/Route with the GOTO Key
If a waypoint or route is selected with the GOTO key, navigation starts to that waypoint.
Routes created with GOTO key are stored as temporary route with route number 21
The waypoint can be selected by the following methods.
(1) Set HOME PORT as the waypoint.
(2) Enter the waypoint number.
(3) Enter the route number.
(4) Set the cursor position as the waypoint
(5) Select from each list (waypoint list and route list).
GOTO
(1) Set HOME PORT as the waypoint
HOME sets the HOME PORT registered at the waypoint number 001 as the waypoint.
If a waypoint is registered as HOME, it can be easily set as a waypoint.
If HOME PORT is not registered, "HOME PORT" will not be displayed.
1. Press
the
key.
2. Press
the
key to select "HOME PORT," and press the
key.
3. Press
the
key to select "RADIUS", "WIDTH" and "GC/RL", and press the
key.
Please refer to "4.5.2 Creating Routes" for details.
4. Press
the
key to select "START," and press the
key.
Navigation will start with the HOME PORT as the waypoint.
Procedure
Содержание JLR-7600
Страница 2: ......
Страница 11: ...ix...
Страница 16: ......
Страница 20: ...1 4 1 4 Construction NWZ 4610 Display Unit Unit mm Mass Approximately 0 8 kg NWZ 4610 Desktop type...
Страница 23: ...1 7 NBD 577C Power Supply Outline Drawing Unit mm Mass Approximately 5 4 kg...
Страница 27: ...1 11 NQA 4351 Output Buffer Outline Drawing Unit mm Mass Approximately 0 8 kg...
Страница 29: ...1 13 NCZ 1663 Select Switch Unit mm Mass Approximately 0 2 kg...
Страница 30: ...1 14 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg...
Страница 31: ...1 15 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg...
Страница 32: ...1 16 CQD 10 Junction Box Outline Drawing Unit mm Mass Approximately 1 1 kg 4 7 5 Installation Screw M6...
Страница 33: ...1 17 NKG 94 Printer Outline Drawing Unit mm Mass 2 2 kg or less Printer Rack...
Страница 38: ...2 4...
Страница 42: ...3 4...
Страница 138: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more...
Страница 158: ...6 30...
Страница 160: ...7 2...
Страница 162: ...8 2...
Страница 181: ......
Страница 182: ......
Страница 183: ......