Individual tests
5.5 Power
supply
In this test the voltage between CAN_V+ and CAN_GND is measured. The meas-
uring range is given in section 10.1.
The measurement is not analyzed because the external power supply via CAN_V+
is optional.
For the measurement of the power supply, you can connect the CANcheck to the
CAN network at any point.
•
If there is a free SUB-D9 socket in the CAN network, you can connect the
CANcheck to this socket via the 1-to-1 cable.
•
If this is not the case, you can loop in the CANcheck between any CAN node
and the CAN network via the Y cable.
Please put the CAN network into operation before you measure the power sup-
ply.
Please select the menu item "Power supply" with the keys UP and DOWN and
press the OK key. Then the test result is displayed immediately.
Individual tests
▼
-Wiring test
-Term. resistors
-Line length
-Line impedance
-Power supply
-Baudrate detection
Power supply
CAN_V+ -> CAN_GND
0.0 V
Copyright IXXAT Automation GmbH
CANcheck Manual, Version 1.2
34