9
-
Mode
Mode
MAN (Manual)
EXT (External)
Changeover
Entering by keys (EXT, START/STOP)
Function
Parameters
EXT :
Digital input pulse multiply
1 : n
n = 1 - 999
Digital input pulse dividing
n : 1
n = 999 - 1
Analog input SET point1 : Current 0 - 20 mA
Stroke rate 0 - 360 spm
SET point2 : Current 0 - 20 mA
Stroke rate 0 - 360 spm
MAN : Stroke rate 0 - 360 spm
Keys
4 keys (START/STOP, EXT,
▲
,
▼
)
Upper limited spm
360 spm
Stop
By receiving stop signal from outside
Indication
Display
4 digit 14 segment LCD
Stroke
Green LED
Input
Stop signal
No voltage contact pulse signal
Pulse
No voltage contact pulse signal
Output
Power source for sensor
12VDC 10 mA or less
Power
source
AC 100 : AC 90 - 127 V, AC 110/AC 115 : AC 90 - 127 V,
AC 200 : AC 180 - 242 V, AC 230 : AC 198 - 264 V
•
Pump specifications
Output
Stroke
Model
capacity
length %
(ml/min)
E
340
520
750
1250
Output per
Maximum
Stroke
Stroke
Pressure
frequency
(ml/stroke)
(MPa)
0.19 ~ 0.94
1
0.29 ~ 1.44
0.7 (0.6)
0.42 ~ 2.08
0.4
0.69 ~ 3.47
0.2
30
35 (SH)
45
55
(spm)
(mm)
0 ~ 360
20 ~ 100
(0.3~1.5 mm)
Note 1.
The performance data is based on clean water at 25 °C under rated voltage.
Note 2.
Capacity is that at the max. pressure. (at max. stroke length and max. stroke frequency)
Capacity exceeds the value at max. pressure when pump operates under low pressure.
Note 3.
Operating ambient temperature : 0 ~ 40 °C
Relative humidity : 30 % to 90 % non-condensing
Note 4.
Liquid temperature : PVC/PVDF 0 °C ~ 40 °C (PC/SH : 0 °C ~ 60 °C)
Note 5.
Permissible voltage fluctuation : Within
±
10 % of rating
*Please note that for the purpose of improvement, parts which have no effect on specifications and fitting
sizes are subject to change without prior notice.
*For SH type, install air chamber of approx. 500 ml volume at the location as close to pump discharge port.
Adjustment Range
Recommended stroke length adjustment range
20 % to 100 %
Recommended frequency adjustment range
0 to 360 stroke per minute
•
Control unit specifications