34
-
Notes to Overview Operating Scheme
1) ------> means automatic movement. After the program Ver is displayed, it automatically moves to the sta-
tus at which the power was off last time. (When the pump is powered for the first time, it comes to WAIT
mode.)
2) For the pump start by manual operation, push START/STOP key at WAIT mode. To stop the pump, push
START/STOP key again.
3) EXT operation starts by pushing EXT key at WAIT mode and stops by pushing START/STOP key.
4) For the switching over between analog and digital operation, push EXT and
▲
keys simultaneously.
Parameter is changed by
▲
and
▼
keys and the set value is fixed by START/STOP key.
5) To move to pulse memory switching mode, push EXT key while DIG is selected at analog/digital switching
mode. (If ANA is selected, you can not come to this mode.)
Figures are changed by
▲
and
▼
keys and switching between multiply and dividing is done by EXT key.
Push START/STOP key to return to WAIT mode.
Initial parameter value
When the pump is shipped from our factory, each parameter value is set as shown on table below.
Mode
Parameter
Initial value
Setting range
Step
Manual
spm
1 - 360
A/D switching
Digital/Analog
Pulse memory
Dividing
switching
Multiply
ON, OF
EXT operation
Dividing
360
1
dIG
DIG, ANA
/OF
ON, OF
×
ON
/1
1 - 999
1
Multiply
×
1
1 - 999
1
Analog
Set point 1 Amp. : 4.0
0.0 - 20.0
0.1
Set point 1 spm : 0
0 - 360
1
Set point 2 Amp. : 20.0
0.0 - 20.0
0.1
Set point 2 spm : 360
0 - 360
1