38
-
(12) Push START/STOP key to confirm the set value and
move to WAIT mode.
(13) Push EXT key to start the pump.
Pump operates according to the set current value. WAIT
disappears and ON lamp blinks.
Display shows the stroke rate at which the pump oper-
ates and EXT word lights. Stroke rate changes corre-
sponding to input current.
To stop the pump, push START/STOP key and WAIT
word lights.
To start the pump next time, push EXT key.
Alarm indication
At the analog input operation, if the current exceeding
360 spm comes, the word OVER lights. While the OVER
is lighting, the pump operates at 360 spm.
When analog input being set, if the same value (current or
stroke rate) is put for SET point 1 and 2, ERR 1 is dis-
played for three seconds and then returns to set display.
2. Pulse multiply operation
(1) Power ON
Power on and green lamp lights, display shows “V3.0E”
and then shows stroke rate of manual operation and goes
to WAIT mode.
(In case the pump is powered for the first time)
The word WAIT is lit at WAIT mode. If it does not show
WAIT, push START/STOP key once to change to WAIT
mode.
EXT
START/STOP
EH-E
ON
EXT STOP OVER SET
1
2
WAIT
360
EXT
START/STOP
EH-E
ON
STOP OVER
Blink
SET
1
2
WAIT
20
EXT
EXT
START/STOP
EH-E
ON
STOP
SET
1
2
WAIT
360
EXT
OVER
EXT
START/STOP
EH-E
ON
STOP
SET
1
2
WAIT
ERR
EXT
OVER
EXT
START/STOP
EH-E
ON
EXT STOP OVER SET
1
2
WAIT
360