20
-
3. Install the pump at the place convenient for the
maintenance/inspection works in the future.
Securely fix the pump so that the pump can not
vibrate horizontally.
4. Use the tube corresponding to the pump suction
and discharge port sizes. Securely connect the
tube so that liquid can not leak or air can not be
sucked in.
5. Make bleeding when you use the pump for the
first time or when you replaced the chemical
tank.
Refer to item “Bleeding procedure” on page.
6. When you disassemble the pump head, replace
diaphragm, O ring, valve gasket and valve unit by
new ones.
7. Do not wipe the pump body with the cloth in
which is soaked by solvent such as benzene,
kerosene or thinner. Otherwise, the body may be
discolored. To clean pump body, use dry cloth or
the cloth in which are soaked by water or neutral
detergent.
Caution
Liquid splash on driving unit and control unit
may cause failure or accident. Pay attention
the liquid not to be splashed.
Benzene
Thinner