43
-
(7) Switching of operation mode
Push EXT key and
▼
key simultaneously, and / 1 (Pulse
dividing operation mode) is displayed and SET lights.
If X1 (multiplying mode) is displayed, push EXT key to
change to / 1.
(Every time EXT key is pushed, the display changes from
X1 to / 1.)
(8) Setting of dividing ratio
Set the dividing ratio with
▲
key and
▼
key.
▲
key increases the number and
▼
key decreases the
number. The number changes slowly one by one if key is
pushed in a short time and changes rapidly if pushed
more than 3 seconds. Set range is 1 to 999. The pump is
set at 1 when it is shipped from the factory.
(9) Push START/STOP key to confirm the operation mode
and dividing ratio.
(10) Setting of upper stroke rate
Stroke rate at pulse dividing operation is the one which is
set for manual operation mode. At WAIT mode, push
▲
key and
▼
key to set the stroke rate. Refer to the item of
Manual Operation for details.
The pump is set at 360 spm when it is shipped from the
factory.
EXT
START/STOP
EH-E
ON
EXT STOP OVER
WAIT
1
2
SET
EXT
START/STOP
EH-E
ON
EXT STOP OVER
WAIT
X
1
2
SET
EXT
START/STOP
EH-E
ON
EXT STOP OVER
WAIT
5
1
2
SET
EXT
START/STOP
EH-E
ON
EXT STOP OVER SET
1
2
WAIT
360
EXT
START/STOP
EH-E
ON
EXT STOP OVER SET
1
2
WAIT
350