35
-
2-2. Setting and Operation of Controller
■
Manual operation
(1) Power ON
When the power is on, a green lamp lights up and the word-
ing “V3.0E” appears, then the stroke rate for manual opera-
tion is displayed and comes to WAIT mode. (In case the
pump is powered on for the first time.) If it does not come to
WAIT mode, push once START/STOP key to come to WAIT
mode.
(2) Stroke rate can be changed by pushing
▲
or
▼
key at wait
mode or during operation. Push
▲
key to increase stroke
rate and
▼
key to decrease. If you push the key in a short
time, the spm figures changes slowly by one spm and if you
continue to push over three seconds, they change quickly.
The pump is shipped set at 360 spm.
When the spm value is changed, the value is not put in mem-
ory unless you push START/STOP key or EXT key, or until
three or more seconds have passed.
(3) Push START/STOP key to start the pump.
WAIT word disappears and ON lamp blinks.
(4) Stop the pump.
When START/STOP key is pushed once, the pump stops and
WAIT word appears to come to WAIT mode.