39
-
(2) Move to EXT operation mode.
Push
▲
key and EXT key simultaneously.
The word dIG is displayed and SET lights.
(If the word ANA is displayed, push
▼
key to change to
dIG. Every time you push
▼
key, the words ANA and
dIG switch over.) When the pump is shipped from the
factory, it is set at dIG.
(3) Move to pulse memory (The function to put in memory
the pulses (max. 255 pulses) which come while the pump
does the multiply operation.)
Push EXT key and /-- OF or / -- ON is displayed and SET
lights. (If X -- ON or X -- OF is displayed, go to next (4).
When the pump is shipped from the factory, it is set at /
-- OF.
Push EXT key and the display changes to X -- ON or X --
OF. (Every time you push EXT key, / -- OF or / -- ON, X
-- ON or X -- OF switches.) When the pump is shipped
from the factory, it is set at X -- ON.
(4) Setting of pulse memory ON, OFF
Push
▲
key and
▼
key to set ON and OFF of pulse memo-
ry. Display X -- ON is memory ON and X -- OF is memo-
ry OFF status.
When the pump is shipped from the factory, it is set at X
-- ON.
(5) Push EXT key to confirm ON, OFF of pulse memory and
return to EXT operation mode.
The display shows dIG and SET lights.
(6) Push START/STOP key to confirm the digital mode and
move to wait mode.
EXT
START/STOP
EH-E
ON
EXT STOP OVER
WAIT
1
2
I G
SET
EXT
START/STOP
EH-E
ON
EXT STOP OVER
WAIT
-- OF
1
2
SET
EXT
START/STOP
EH-E
ON
EXT STOP OVER
WAIT
X-- ON
1
2
SET
EXT
START/STOP
EH-E
ON
EXT STOP OVER
WAIT
X -- OF
1
2
SET
EXT
START/STOP
EH-E
ON
EXT STOP OVER
WAIT
1
2
I G
SET
EXT
START/STOP
EH-E
ON
EXT STOP OVER SET
1
2
WAIT
360