13
-
Display examples
Meanings
EXT
STOP OVER
SET
1
2
WAIT
5
I
Running at EXT operation mode (Dividing).
Display shows running at 5 : 1 dividing.
EXT
STOP OVER
SET
1
2
WAIT
Running at EXT operation mode (Analog input 0 - 20 mA).
Display shows running at 120 spm speed responding to input current.
EXT
STOP OVER
SET
1
2
WAIT
5
I
•
Alarm display
Display examples
Meanings
Display for excess spm at EXT operation (analog input operation).
In analog input operation, visible if external signal exceeding 360 spm opera-
tion comes. While visible, pump runs at fixed speed of 360 spm.
Display for excess spm at EXT operation (Pulse multiply operation).
In multiply operation, visible if next pulse comes when the pump is making
the strokes. While visible, max. 255 pulses can be put in storage. You can
set not to put them in storage.
Display for excess spm at EXT operation (Pulse dividing operation).
In dividing operation, visible if signal which exceeds max. preset number of
strokes comes. While visible, the pump runs at fixed max. number of
strokes. You can set so that excessive input pulses can be put in storage up
to 255 pulses.