12
-
•
Controller display and panel
EXT
START/STOP
EH-E
ON
WAIT EXT STOP OVER SET
Alpha/numeric display
1
2
STOP indicator
Over indicator
EXT indicator
WAIT indicator
START/STOP key
ON light
EXT key
SET indicator
DOWN key
UP key
Visible when pump is
operating via external
input.
Visible when pump
is in WAIT mode.
Indicates stroke frequency, or
external mode or external
settings.
Visible when the
pump is stopped via
external signal. The
pump stops when
visible.
Visible when signal exceeds
the 360 spm capability.
Increases numeric values.
Used with EXT key to select
external modes.
SET point indicator
Visible when SET point 1 and
2 are set at EXT mode and
analog input (0 - 20mA)
operation.
Decreases numeric values.
Used with EXT key to select
external setting mode.
Visible when pump
external mode
and/or settings are
being selected.
Push to set pump
for external input
operation.
Manually starts or
stops the pump.
This key is used in
setting external modes.
Indicates power to
the pump and blinks
with each stroke.
•
Basic display
Display examples
Meanings
Running at manual operation mode.
Value shows set spm.
Waiting at WAIT mode.
Displayed value is set value at manual operation mode.
Running at EXT operation mode (Pulse multiply).
Display shows running at 1 : 5 multiply.
WAIT
EXT
STOP OVER
SET
1
2
360
EXT
STOP OVER
SET
1
2
360
WAIT
EXT
STOP OVER
SET
1
2
X 5
WAIT
5. Controller Display