Maintenance Instructions

3196CC

Содержание Goulds Pumps 3196CC

Страница 1: ...Installation Operation and Maintenance Instructions 3196CC ...

Страница 2: ......

Страница 3: ...eling worksheet 17 3 5 Grout baseplate 18 3 5 1 Alignment check 18 3 6 Piping 19 3 6 1 General 19 3 6 2 Suction piping 20 3 6 3 Discharge piping 23 3 7 Final piping check 24 4 Operation 25 4 1 Preparation for Start up 25 4 2 Checking rotation 25 4 2 1 Check impeller clearance 25 4 2 2 Shaft sealing 25 4 2 3 Priming pump 28 4 2 4 Other methods of priming 31 4 2 5 Start up precautions 31 4 3 Startin...

Страница 4: ... 6 6 Remove inboard labyrinth oil seal 333A 45 6 7 Inspections 46 6 7 1 Casing 46 6 7 2 Impeller 47 6 7 3 Seal Chamber Stuffing Box Cover 48 6 7 4 Frame adapter 50 6 8 Reassembly 50 6 9 Reassembly 51 6 10 All models STX MTX LTX XLT X X17 63 6 11 Reinstall Back Pull Out Assembly 63 6 12 Impeller Adjustment 64 6 13 Assembly Troubleshooting 64 6 14 Parts list with materials of construction 65 6 15 Mo...

Страница 5: ...om en US Tools and Resources Litera ture or by contacting your nearest Goulds Pumps sales representative These manuals must be read and understood before installation and start up For additional information contact your nearest Goulds Pumps sales representative or visit our Web site at https www gouldspumps com 1 2 Safety warnings Specific to pumping equipment significant risks bear reinforcement ...

Страница 6: ...tes a hazardous situation which if not avoided could result in death or serious injury Example Pump shall never be operated without coupling guard installed correctly CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury Example Throttling flow from the suction side may cause cavitation and pump damage Electrical Hazard WARNING Indicates the possibil...

Страница 7: ...ING NEVER run pump below recommended minimum flow when dry or without prime WARNING ALWAYS lock out power to the driver before performing pump maintenance WARNING NEVER operate pump without safety devices installed WARNING NEVER operate pump with discharge valve closed WARNING NEVER operate pump with suction valve closed WARNING DO NOT change service application without approval of an authorized I...

Страница 8: ...rs of the proper size and material WARNING Replace all corroded fasteners WARNING Ensure all fasteners are properly tightened and there are no missing fasten ers WARNING Startup and Operation When installing in a potentially explosive environment please ensure that the motor is properly certified WARNING Operating pump in reverse rotation may result in contact of metal parts heat generation and br...

Страница 9: ...oid physical injury and or equipment damage Steel toed shoes must be worn at all times WARNING The pump may handle hazardous and or toxic fluids Observe proper decon tamination procedures Proper personal protective equipment should be worn Precautions must be taken to prevent physical injury Pumpage must be han dled and disposed of in conformance with applicable environmental regula tions WARNING ...

Страница 10: ...ectrical equipment installed in Europe ATEX deals with the control of potentially explosive atmospheres and the standards of equipment and protective systems used within these atmospheres The relevance of the ATEX re quirements is not limited to Europe You can apply these guidelines to equipment installed in any poten tially explosive atmosphere Guidelines for compliance Compliance is fulfilled on...

Страница 11: ...and contact your ITT Goulds Pumps sales representative before proceeding The CE and the Ex designate the ATEX compliance The code below reads as follows II Group Non Mining Equipment 2 Category 2 G D Gas and Dust present T4 Temperature class can be T1 to T6 see Table The code classification marked on the equipment must be in accordance with the specified area where the equipment will be installed ...

Страница 12: ...rd The pump is mounted on the casing feet as well as the motor for solid support Flange to flange dimensions meet ANSI B73 The impeller is fully open and threaded to the shaft Threads are sealed from the pumpage by an 0 ring PTFE The impeller is the same as used in the con ventional Models 3196 and 3796 with the exception it has an anti rotation op tion 3796 CC The casing is top centerline dischar...

Страница 13: ...on Every pump has a Goulds nameplate that provides information about the pump The nameplate is locat ed on the casing Pump Casing Tag provides information about the pump s hydraulic characteristics Note the format of the pump size Discharge x Suction Nominal maximum Impeller Diameter in inches Example 2x3 8 Figs 2 3 Figure 2 English nameplate Figure 3 Metric nameplate 2 4 Receiving the pump Inspec...

Страница 14: ...his service can be supplied by contracting your local Goulds sales representatives 2 4 2 Handling WARNING Pump and components are heavy Failure to properly lift and support equipment could result in serious physical injury or damage to pumps Steel toed shoes must be worn at all times Use care when moving pumps Lifting equipment must be able to adequately support the entire assem bly Hoist bare pum...

Страница 15: ...Figure 5 Proper lifting of pump using slings 2 4 Receiving the pump 3196CC Installation Operation and Maintenance Instructions 13 ...

Страница 16: ...e foundation must be able to absorb any vibration and to form a permanent rigid support for the pumping unit The location and size of the foundation bolts are shown on the outline assembly drawing provided with the pump data package Foundation bolts commonly used are sleeve type Figure 6 Sleeve type foundation bolts on page 14 and J type Figure 7 J type foundation bolts on page 15 Both designs per...

Страница 17: ...r and or debris from anchor bolt holes sleeves prior to grouting If the sleeve type bolts are being used fill the sleeves with packing or rags to prevent grout from entering Figure 8 3 Carefully lower baseplate onto foundation bolts 4 Level baseplate to within 3 2mm 125 in over length of the baseplate and to within 1 5mm 088 in over the width of the base by adjusting wedges 5 A level should be pla...

Страница 18: ...Figure 9 3 3 Level baseplate 16 3196CC Installation Operation and Maintenance Instructions ...

Страница 19: ..._____________ 7 ____________________ 8 ____________________ 9 ____________________ 10 ___________________ 11 ___________________ 12 ___________________ 13 ___________________ 14 ___________________ 15 ___________________ 16 ___________________ 17 ___________________ 18 ___________________ Level measurements 3 4 Baseplate leveling worksheet 3196CC Installation Operation and Maintenance Instructions...

Страница 20: ...p to level of dam Remove air bubbles from grout as it is poured by puddling using a vibrator or pumping the grout into place Non shrink grout is recom mended 4 Allow grout to set 5 Fill remainder of baseplate with grout Remove air as before Fig 11 Figure 11 6 Allow grout to set at least 48 hours 7 Tighten foundation bolts 3 5 1 Alignment check Re check alignment before continuing using methods pre...

Страница 21: ...ctions of the pump This may im pose dangerous strains on the unit and cause misalignment between pump and driver Pipe strain will adversely effect the operation of the pump resulting in physical injury and damage to the equipment 1 All piping must be supported independently of and line up naturally with the pump flanges 2 Piping runs should be as short as possible to minimize friction losses Figur...

Страница 22: ... pipe parts valves and fittings and pump branches prior to assembly 3 6 2 Suction piping WARNING NPSHA must always exceed NPSHR as shown on Goulds performance curves received with order Reference Hydraulic Institute for NPSH and pipe fraction values needed to evaluate suc tion piping Properly installed suction piping is a necessity for trouble free pump operation Suction piping should be flushed b...

Страница 23: ...ith a reducer at the suction flange Suction piping should never be of smaller diameter than the pump suction 3 Reducers should be eccentric at the pump suction flange with sloping side down and horizontal side at the top Fig 16 17 18 3 6 Piping 3196CC Installation Operation and Maintenance Instructions 21 ...

Страница 24: ...iners when used must have a net free area of at least three times the suction pipe area 5 Separate suction lines are recommended when more than one pump is operating from the same source of supply Figure 17 3 6 Piping 22 3196CC Installation Operation and Maintenance Instructions ...

Страница 25: ...iping should extend below pump suction flange 5 The size of entrance from supply should be one or two sizes larger than the suction pipe 6 The suction pipe must be adequately submerged below the liquid surface to prevent vortices and air entrainment at the supply 3 6 3 Discharge piping 1 Isolation and check valves should be installed in discharge line Locate the check valve between isolation valve...

Страница 26: ... After connecting the piping to pump 1 Rotate shaft several times by hand to be sure that there is no binding and all parts are free 2 Check alignment per the alignment procedure outlined previously to determine absence of pipe strain If pipe strain exists correct piping 3 7 Final piping check 24 3196CC Installation Operation and Maintenance Instructions ...

Страница 27: ...he pump reassembly per the instructions in 6 Disassembly reassembly on page 38 5 Tighten the set screws in the seal locking ring to secure the seal to the shaft 6 Remove the centering clips from the seal Conventional Inside Component Mechanical Seal 1 Assemble the seal chamber per the instructions in 6 Disassembly reassembly on page 38 2 Apply bluing to the shaft sleeve at the face of the seal cha...

Страница 28: ...ructions in 6 Disassembly reassembly on page 38 2 Apply bluing to the shaft sleeve at the face of the seal chamber 3 Continue the complete reassembly of the pump less the mechanical seal 4 Set the impeller clearance per the instructions in 4 Operation on page 25 5 Scribe a line on the blued shaft sleeve at the face of the seal chamber 6 Remove the casing impeller and seal chamber per the instructi...

Страница 29: ...C pumps are shipped without packing lantern ring or split gland instal led These are included with the box of fittings shipped with the pump and must be installed before start up Installation of Packing 1 Carefully clean stuffing box bore 2 Twist the packing just enough to get it around the shaft Fig 19 20 Figure 19 Figure 20 3 Insert packing staggering the joints in each ring by 90 4 The stuffing...

Страница 30: ...rce is under a vacuum Under these conditions packing will not be cooled and lubricated and air will be drawn into the pump If an outside source of clean compatible liquid is required the pressure should be 15 psi 1 0 kg cm2 above the suction pressure The piping should be connected to the lantern ring connection with a 40 60 drops per minute leak rate NOTICE Most packing requires lubrication Failur...

Страница 31: ...n Supply Below Pump Except 3796 A foot valve and outside source of liquid may be used to prime the pump Outside source of liquid can come from a priming pump pressurized discharge line or other outside supply Fig 23 and 24 Figure 23 4 2 Checking rotation 3196CC Installation Operation and Maintenance Instructions 29 ...

Страница 32: ...ot require the use of a foot valve in the suction line Refer to the pump s performance curve to determine the time required for priming 1 Close discharge valve and open air vents in casing 4 2 Checking rotation 30 3196CC Installation Operation and Maintenance Instructions ...

Страница 33: ...adjusted or checked for speed governor or overspeed trip settings while coupled to the pump at initial start up If settings have not been verified uncouple the unit and refer to driver manufacturer s instructions for assistance 5 Running a new or rebuilt pump at slow speeds may not provide enough flow to adequately flush and cool the stuffing box bushing s close running surfaces 6 Pumpage temperat...

Страница 34: ...l injury Damage occurs from 1 Increased vibration levels Affects bearings stuffing box or seal chamber and mechanical seal 2 Increased radial loads Stresses on shaft and bearings 3 Heat build up Vaporization causing rotating parts to score or seize 4 Cavitation Damage to internal surfaces of pump 4 4 3 Operating under freezing conditions Exposure to freezing conditions while pump is idle could cau...

Страница 35: ...ions Check the foundation and the hold down bolts for tightness If the pump has been left idle check the packing Replace if required 5 6 Annual inspections Check the pump capacity pressure and power If pump performance does not satisfy your process requirements and the process requirements have not changed the pump should be disassembled inspected and worn parts should be replaced Otherwise a syst...

Страница 36: ...split gland Insert single packing rings by twisting as shown in Figure 19 on page 27 Press each ring to ensure proper compression in the stuffing box Stagger joints 90 Lightly and evenly tighten the gland Excessive tightening will result in premature failure of the packing and shaft sleeve After packing it must be possible to rotate shaft by hand Final adjustment of packing gland is made after pum...

Страница 37: ...clos est size greater 6 Loosen the motor locking bolts 370B Using the jacking bolts 370D back the motor 338 away from the pump until enough space is available to insert the shim s 329B 7 Insert the shim s 329B around the motor locking bolts Fig 27 Figure 27 8 Loosen the jacking bolts 370D 9 Tighten the motor 338 locking bolts securely 10 Check shaft for free turning 5 9 Feeler gauge method all but...

Страница 38: ...e greater 6 Loosen the jacking bolts 370D Tighten motor locking bolts 370B securely 7 Check shaft for free turning Table 4 Impeller Clearances Cold Temoerature Clearances for Various Service Temoeratures inches Imm Service Temoerature 3196 LF3196 CV3196 1 3796 STX MTX LTX XLTX X17 STXMTX LT X STX MTX LTX XLTX STXMTX LT X inches mm inches mm in ches mm in ches mm In ches mm in ches mm 20 to 150 F 2...

Страница 39: ...r or vapor pockets in suction line Rearranqe pipinq to eliminate air pockets Air leak in suction line Repair plua leak Pump is noisy or vibrates Improper pump driver alionment Alion shafts Partly cloqqed impeller causinq imbal ance Back flush pump to clean impeller Broken or bent impeller or shaft Replace as required Foundation not rigid Tighten hold down bolts of pump and mo tor or adjust stilts ...

Страница 40: ...vent physical injury Pumpage must be han dled and disposed of in conformance with applicable environmental regulations NOTICE Before disassembling the pump for overhaul ensure all replacement parts are available WARNING Lock out power supply to driver motor to prevent accidental startup and physical injury 1 Shut off all valves controlling flow to and from pump WARNING Operator must be aware of pu...

Страница 41: ...sembly NOTICE Penetrating oil can be used if adapter to casing joint is excessively corroded NOTICE Remove and then mark shims from under motor foot Save for reassembly WARNING Never remove the back pull out assembly unassisted physical injury can occur 8 Remove casing gasket 351 and discard Replace with new gasket during reassembly 9 Remove jack screws 418 NOTICE Casing gasket 351 may partially a...

Страница 42: ...use physical injury STX MTX LTX 1 Remove impeller anti rotation nut 458Y from front of impeller This part will need to be replaced for proper sealing Fig 30 Figure 30 2 Spray penetrating oil through the plug hole into the cavity at the end of the shaft Wait 15 mi nutes Rotate the shaft several times while waiting to distribute the oil 3 Slide wrench over the shaft at location of flats Fig 31 6 2 D...

Страница 43: ...he impeller counterclockwise viewed from the impeller end of the shaft impacting the wrench handle until the impeller loosens Fig 30 6 Remove impeller 0 ring 412A and discard Replace with a new o ring during reassembly Fig 32 and 33 Figure 32 6 2 Disassembly 3196CC Installation Operation and Maintenance Instructions 41 ...

Страница 44: ...0H 3 Remove seal chamber 184 Fig 34 Figure 34 4 Remove shaft sleeve 126 if used NOTICE Mechanical seal is attached to sleeve 126 Rotary portion of seal needs to be removed from sleeve by loosening set screws and sliding it off the sleeve Refer to mechanical seal instruc tions 5 Remove gland 250 with stationary seat and 0 ring 360Q 6 3 Removal of seal chamber cover mechanical seal 42 3196CC Install...

Страница 45: ... 6 4 Removal of stuffing box cover packed box 1 Remove gland stud nuts 355 and gland 107 2 Remove stuffing box cover stud nuts 370H 3 Remove stuffing box cover 184 Fig 36 Figure 36 4 Remove shaft sleeve 126 Fig 37 6 4 Removal of stuffing box cover packed box 3196CC Installation Operation and Maintenance Instructions 43 ...

Страница 46: ...184 No lantern ring is pro vided with self lubricating graphite packing Figure 38 6 5 Remove frame adapter 1 Remove motor lock bolts 3708 and shims 2 Carefully remove frame adapter 108 Fig 40 6 5 Remove frame adapter 44 3196CC Installation Operation and Maintenance Instructions ...

Страница 47: ...ing fit into the bearing frame 228A for STX frame adapter 108 for MTX LTX XLT X and X17 Remove 0 rings 497H 497J if necessary Figure 40 NOTICE Labyrinth oil seal O rings 497H J are part of 3196 maintenance kits or can be obtained sepa rately 6 6 Remove inboard labyrinth oil seal 333A 3196CC Installation Operation and Maintenance Instructions 45 ...

Страница 48: ...ed NOTICE Clean parts in solvent to remove oil grease or dirt Protect machined surfaces against damage during cleaning 6 7 1 Casing The casing 100 should be inspected for cracks and excessive wear or pitting It should be repaired or replaced if it exceeds the following criteria Fig 41 Fig 42 and Fig 43 Figure 41 Figure 42 6 7 Inspections 46 3196CC Installation Operation and Maintenance Instruction...

Страница 49: ...egularities 6 7 2 Impeller 1 Inspect impeller 101 vanes for damage Replace if grooved deeper that 1 16 in 1 6 mm or if worn evenly more than 1 32 in 8 mm Area a in Fig 44 Figure 44 2 Inspect pumpout vanes for damage Replace if worn more than 1 32 in 8 mm Area b in Fig 44 45 6 7 Inspections 3196CC Installation Operation and Maintenance Instructions 47 ...

Страница 50: ...TICE For CV 3196 impeller the face of the impeller is cast not machined The face runout need not be checked 6 7 3 Seal Chamber Stuffing Box Cover 1 Make sure seal chamber stuffing box cover 184 gasket surface is clean at adapter face Figs 46 47 48 Figure 46 6 7 Inspections 48 3196CC Installation Operation and Maintenance Instructions ...

Страница 51: ...Figure 47 Figure 48 2 Replace if there is any pitting or wear greater than 1 8 in 2 mm deep 6 7 Inspections 3196CC Installation Operation and Maintenance Instructions 49 ...

Страница 52: ... Make sure gasket surface is clean Figure 49 6 8 Reassembly Refer to following table for torque values while reassembling pump Table 5 Maximum Torque Values in ft lb Nm for Casing Bolts 370 Models 3196 CV 3196 LF 3196 3796 with 150 lb Casing flanges Model HT 3196 and all Mod els 6 8 Reassembly 50 3196CC Installation Operation and Maintenance Instructions ...

Страница 53: ...5 X17 7 8 113 153 170 231 141 191 212 287 330 447 495 671 Motor to Adapter 20 27 30 40 20 27 30 40 Values are in inch Lbs Nm 6 9 Reassembly 1 Insert jacking bolts 370D 2 Install frame adapter 108 onto motor Align bolt holes with those on frame Fig 49 Figure 50 3 Install motor locking bolts 370B Hand tighten bolts with a wrench CAUTION Do not overtighten at this point 4 Check adapter fits Rotate sh...

Страница 54: ...n O ring fit Position the labyrinth seal drain slots at the bottom 6 o clock position Fig 51 Figure 52 NOTICE For detailed labyrinth seal installation instructions see Appendix Labyrinth Seal Installation In structions 6 9 Reassembly 52 3196CC Installation Operation and Maintenance Instructions ...

Страница 55: ...indicator reading is greater than 0 005 in 13 mm determine cause and correct before proceeding Fig 53 8 Install shaft sleeve 126 if used Fig 54 55 NOTICE Make sure sleeve is fully seated WARNING Wear a heavy set of work gloves when handling impeller 101 as sharp edges may cause physical injury 6 9 Reassembly 3196CC Installation Operation and Maintenance Instructions 53 ...

Страница 56: ...shaft to stop rotation When impeller 101 makes firm contact with sleeve 126 turn the wrench counterclockwise viewed from impeller end of shaft and slam it down A few sharp raps will tighten impeller 101 properly Fig 56 6 9 Reassembly 54 3196CC Installation Operation and Maintenance Instructions ...

Страница 57: ...mpel ler pumpout vanes 101 Fig 57 Figure 58 13 Take the measurement just attained and subtract 14 0 030 in 0 76mm from it Select shim s equal to or next greater to this number 15 The goal is to have a gap of as close to 0 030 in 0 76 mm as possible between the seal cham ber and back of the impeller pumpout vanes 16 Blue the shaft sleeve 126 or shaft 122 if no sleeve is used Scribe a mark at gland ...

Страница 58: ...f setting 17 Check impeller 101 runout Check vane tip to vane tip If total indicator reading is greater than 0 005 in 13 mm determine cause and correct before proceeding Fig 57 Figure 60 18 Remove impeller 101 and shaft sleeve 126 if used Fig 59 6 9 Reassembly 56 3196CC Installation Operation and Maintenance Instructions ...

Страница 59: ...or shaft sleeve 126 per seal manufacturer s instructions In stall shaft sleeve 126 if used with seal NOTICE Anti galling compound can be applied to the sleeve bore to aid in disassembly 21 Install seal chamber cover 184 with nuts 370H Fig 62 6 9 Reassembly 3196CC Installation Operation and Maintenance Instructions 57 ...

Страница 60: ...rench on shaft When impeller 101 makes firm contact with sleeve 126 raise shaft wrench counterclockwise when viewed from impeller end of shaft and slam it down clockwise when viewed from impeller end of shaft A few sharp raps will tighten impeller 101 properly Fig 63 Figure 64 25 Install Impeller anti rotation device 458Y making sure the 0 ring 428D is in good condition Re place if needed Fig 64 N...

Страница 61: ...l the mechanical seal on the shaft 122 or sleeve if used 126 per the seal manufacturer s instructions Install the sleeve with the seal if used 28 Slide gland and then stationary seat with gaskets on the shaft or sleeve Fig 66 6 9 Reassembly 3196CC Installation Operation and Maintenance Instructions 59 ...

Страница 62: ...h the sleeve raise the shaft wrench counterclockwise when viewed from the impeller end of the shaft and slam it down clockwise when viewed from the impeller end of the shaft A few sharp raps will tighten the impeller properly Fig 68 NOTICE Be sure to use a properly balanced impeller 31 Install Impeller anti rotation device 458Y making sure the 0 ring 428D is in good condition Re place if needed Fi...

Страница 63: ...peller 32 Install the gland 107 with hex nuts 355 Pumps With Packing 33 Install stuffing box cover 184 with nuts 370H Fig 70 Figure 70 34 Install shaft sleeve 126 Fig 71 Figure 71 6 9 Reassembly 3196CC Installation Operation and Maintenance Instructions 61 ...

Страница 64: ... 101 makes firm contact with sleeve 126 raise shaft wrench counterclockwise when viewed from impeller end of shaft and slam it down clockwise when viewed from impeller end of shaft A few sharp raps will tighten impeller properly Fig 72 Figure 72 36 Install Impeller anti rotation device 458Y making sure the 0 ring 428D is in good condition Re place if needed Fig 73 Figure 73 NOTICE Be sure to use a...

Страница 65: ...ts 370 finger tight Casing bolts 370 may be coated with anti galling compound to aid disassembly Tighten the casing bolts per Table 5 Maximum Torque Values in ft lb Nm for Casing Bolts 370 on page 50 torque values Install casing jack screws 418 snug tight Figure 73 on page 62 NOTICE Do not overtighten casing jack screws 418 4 Replace shims under motor frame foot and tighten frame foot to baseplate...

Страница 66: ...s reference chart Material Goulds Pumps Ma terial Code ASTM DIN ISO JIS Cast Iron 1001 A48CLASS20 Ductile Iron 1012 A395 Gr60 40 18 Ductile Iron 1013 A536 Gr60 42 10 CD4MCu 1041 A744 CD4MCU Monel 1119 A494 GrM 35 1 316SS 1203 A744 CF 8M 1 4408 G5121 SC514 Alloy 20 1204 A744CN 7M 1 4500 317SS 1209 A744CG 8M 1 4448 Hastellov C 1215 A494 CW 6M CD4MCu 1216 A744CD4MCU 9 4460 Hastellov B 1217 A494 N 7M ...

Страница 67: ...15 333A Seal Labyrinth Inboard 6842 351 Gasket Casing 5127 353 Stud Gland 2228 355 Nut Gland Stud 2228 357K Nut Stud Cover to Adapter 2228 358 Plug Drain Casing Optional 2229 358A Plug Pipe Flush 2229 360Q Gasket Gland 5108 370 Screw H Cap Adapter to Casing 2228 370B Screw H H Cap Adapt Motor 2228 370D Screw H H Cap Adapt Motor Jacking 2228 370H Stud Cover to Adapter 2228 412A 0 Rina Impeller 6359...

Страница 68: ...6 15 Model 3196 Cross Sectional 6 15 Model 3196 Cross Sectional 66 3196CC Installation Operation and Maintenance Instructions ...

Страница 69: ...6 16 Model CV 3196 Cross Sectional 6 17 Model 3796 Cross Sectional 6 16 Model CV 3196 Cross Sectional 3196CC Installation Operation and Maintenance Instructions 67 ...

Страница 70: ...peller 101 Shaft Sleeve 126 if applicable Casing Gasket 351 Impeller 0 Ring 412A Inboard Labyrinth Seal Rotary 0 Ring 497H Inboard Labyrinth Seal Stationary 0 Ring 497J Lantern Ring Half 105 Packed Stuffing Box Stuffing Box Packing 106 Packed Stuffing Box if applicable Packing Gland 107 Packed Stuffing Box if applicable Impeller Gasket 428D XLT X X17 Impeller Anti Rotation Bolt Shim Packs 4 7 Spar...

Страница 71: ...semble the power end per the instructions in Section 6 Disassembly Reassembly CAUTION The edges of the keyway can be sharp Failure to cover the keyway may result in a cut o ring and a damaged seal 2 Wrap tape around the coupling end of the shaft to cover the keyway NOTICE The smooth surface of electrical tape provides an excellent surface to slide the rotor o ring over Press the seal over the shaf...

Страница 72: ...de diameter of the seal and at the drain slot This is the result of the two surfaces being smoothed similar to burnishing A lubricant should not be applied between the faces at installation Once the running clearance has been established no further wear is experienced and no decrease in seal performance occurs as a result of the car bon PTFE residue 8 2 Installation Procedures 70 3196CC Installati...

Страница 73: ...ww gouldspumps com ITT Goulds Pumps Vertical Products Operation 3951 Capitol Avenue City of Industry CA 90601 1734 USA 2021 ITT Corporation The original instruction is in English All non English instructions are translations of the original instruction Form IOM 3196CC en US 2021 08 ...