Goodrive20-EU series VFD
Function parameters
68
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
Please remember all users' passwords.
Retreat editing state of the function codes and
the password protection will become valid in 1
minute. If the password is available, press
PRG/ESC to enter into the editing state of the
function codes, and then "0.0.0.0.0" will be
displayed. Unless input right password, the
operator cannot enter into it.
Note:
Restoring to the default value can clear
the password, please use it with caution.
P07.01
Parameter
copy
0: No operation
1: Upload the local function parameter to the
keypad
2: Download the keypad function parameter to
local address (including the motor parameters)
3: Download the keypad function parameter to
local address (excluding the motor parameter of
P02 and P12 group)
4: Download the keypad function parameters to
local address (only for the motor parameter of
P02 and P12 group)
Note
: After finish 1
– 4, the parameter will restore
to 0 and the uploading and downloading does
not include P29.
0
◎
P07.02
Key function
selection
0x00
– 0x27
Ones: QUICK/JOG key function
0: Null
1: Jogging
2: Switch display state via shift key
3: Switch between FWD/REV rotation
4: Clear UP/DOWN setting
5: Coast to stop
6: Switch running command ref. mode in order
7: Quick commission mode (based on
non-default parameter)
tens:
0: keys unlocked
1: Lock all keys
0x01
◎