Goodrive20-EU series VFD
Function parameters
100
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P17.26
Current
running time
Display the current running time of the VFD.
Range: 0
– 65535min
●
P17.27
Simple PLC
and present
stage of
multi-step
speed
Display simple PLC and the current stage of the
multi-step speed
Range: 0
– 15
●
P17.28
ASR controller
output
The percentage of the rated torque of the relative
motor, display ASR controller output
Range: -300.0%
– 300.0% (rated motor current)
●
P17.29 Reserved
●
P17.30 Reserved
●
P17.31 Reserved
●
P17.32
Magnetic flux
linkage
Display the magnetic flux linkage of the motor.
Range: 0.0%
– 200.0%
●
P17.33
Exciting current
reference
Display the exciting current reference in the
vector control mode.
Range: -3000.0
– 3000.0A
●
P17.34
Torque current
reference
Display the torque current reference in the vector
control mode.
Range: -3000.0
– 3000.0A
●
P17.35
AC input
current
Display the input current in AC side.
Range: 0.0
– 5000.0A
●
P17.36 Output torque
Display the output torque. Positive value is in the
electromotion state, and negative value is in the
power generating state.
Range: -3000.0Nm
– 3000.0Nm
●
P17.37
Motor overload
counting
0
– 100 (OL1 when 100)
●
P17.38
PID output
Display PID output
-100.00
– 100.00%
●
P17.39
Parameter
download error
0.00
– 99.99
0.00
●
P17.40
Process PID
proportional
gain
0.00
– 100.00
●
P17.41
Process PID
integral time
0.00
– 10.00s
●
P17.42
Process PID
differential time
0.00
– 10.00s
●