SEPAMAT F-SC_Manual_Vers.1.0e_en
31
Appendix 1.2 Bluetooth function in Duplex and Triplex applications
1. Each SMT-F-SC unit is factory initialized, allowing pre-set operation procedures to occur. Is it
still necessary to perform a self-initialization (i.e. after a RESET), after which every device will
be initialized individually (see note below).
2. In order to initiate a Bluetooth connection, the mains plug of all SMT-F-SCs must be inserted
within 10 seconds of each other (all LEDs must be extinguished beforehand).
All Power LEDs flash simultaneously when the connection with the units is obtained. This
procedure lasts for approx. 20 seconds.
3. The systems are now ready to use. The pumps will automatically start as soon as a decrease
in pressure is detected.
4. The desired operating pressure can be adjusted by pressing
+
or
on any one pump
controller. (The Bluetooth connection automatically transfers these settings to the other
devices).
Note:
It is necessary for the
SMT-F-SC
to execute a fresh automatic initialization after every RESET (see
section 5.1.3). It is important that the other parallel connected
SMT-F-SCs
remain plugged in with
Power ON, in order that all units initialize successfully together via Bluetooth.
If there are several devices in the room that operate independent of each other, then the
transmission frequency can be modified (see Setting F20, Chapter 5.1.4). If a pump alone runs for
30 seconds, then the pump control is determined to be "single mode" (F17-3). The Group function
can then be setup, in which F17 is modified.