5
6
User manual
G-LUBE 60, 120, 240
3. Mounting
High backpressure can cause
a delay in dispensing. The
backpressure shall not exceed 5
bar (73 psi).
If the product is installed at a 45°
or 90° angle, please use an angle
adapter greater than or equal to
1/4" (diameter 6-8 mm).
Use a 6 mm (inner diameter) tube
for remote installations. Keep the
maximum distance at 0.5 m (1.5
feet).
G-LUBE is designed for
single
point lubrication only. Direct
mounting is always preferred.
If the application does not
allow direct mounting, remotely
assemble the unit using appro-
priate accessories and keep the
distance from the lube point as
short as possible.
For remote installations use a 6 mm (inner diameter) tube pre-fi lled
with the same or compatible grease as the grease contained in the unit.
6.
Product certifications
5.
Dispensing volume chart
Dispensing
period
Dispensing volume/day
60 ml
120 ml
240 ml
1 month
2.00 ml
4.00 ml
8.00 ml
3 months
0.67 ml
1.33 ml
2.66 ml
6 months
0.33 ml
0.67 ml
1.33 ml
9 months
0.22 ml
0.44 ml
0.89 ml
12 months
0.17 ml
0.33 ml
0.67 ml
The output volume may vary due to unsettled outside infl uences such as
ambient temperature, atmospheric pressure, consistancy of lubricant or
tube lengths.
4.
Important information
Certifi cations
•
The maximum storage temperature should not 40 °C
(+104 °F). Higher temperatures decrease the battery‘s lifespan. The
lubricator has to be activated within two years from receiving.
•
Minimize tube resistances. Narrow passages and right angles
should be avoided.
•
G-LUBE can be re-adjusted or switched off during operation.
•
During operation of G-LUBE a visual inspection of G-LUBE as well
as of the lubrication point must be carried out regularly.
•
G-LUBE may only be used to supply a
single
lubrication point.
No branches may be made. Once the lubricator is installed and
activated it must not be removed and mounted onto another
lubrication point.
•
Product warranty is limited to original defects in material and
workmanship and does not cover any colleteral damage due
to mishandling, abuse and/or any other inappropriate use of
G-LUBE.
Gruetzner GmbH
Kohlenhofstr. 60
•
90443 Nuremberg, GER
•
•
www.G-LUBE.com
ll 1 G Ex ia llC T4 Ga
INERIS 12ATEX0062X
-20°C ≤ Ta ≤ +55°C