2
3
4
5
6
1
2
3
4
6
5
7
9
10
8
1
2
4
8
9
7
10
11
12
13
3
WARNING
•
Locations: intrinsically safe, SÉCURITÉ INTRINSÈQUE; Exia
•
Potential electrostatic charging hazard. Clean with damp cloth
only.
•
Do not change, replace or charge battery cells.
•
Temp. code T4 : -25 ° C ≤ TA ≤ + 55 ° C
•
Substitution of components may impair intrinsic safety
AVERTISSEMENT: LA SUBSTITUTION DE COMPOSANTS PEUT
COMPROMETTRE LA SÉCURITÉ INTRINSÈQUE
•
If ignitable gases are present, only touch with an isolating object
or while wearing an electrostatic grounding device.
•
To prevent ignition of fl amable or combustible atmospheres read,
understand and follow the instructions of this user manual.
Nr. Benennung
1
Housing cap
2
Mode selector
3
Thread 1/4" male
4
Battery cover
5 Battery
Nr. Benennung
6
Printed curcuit board
7 Piston
8
Lubricant reservoir
9 Funnel
10 Plug
1.
Product details
2.
Installation & disposal
Remove any contaminants
around the lube point.
The reliable operation depends on completely fi lled grease
lines. Ensure that the grease lines are not blocked. Therefore, grease
them before starting G-LUBE. Remove any hardened grease by purging
the lube point with a manual grease gun. The grease in the equipment
and the grease in the unit should be the same or compatible.
Ensure a clear passage using a
manual grease gun.
NOTE
Remove the plug.
The lubricator requires a certain start-up time until the
lubricant is fi rst dispensed. The start-up time varies in line with the
volume dispensed, dispenser size and operating temperature.
NOTE
Unscrew the housing cap
counterclockwise.
Note the installation date and
the scheduled date of lube cycle
completion on the label.
When the selected dispensing
period has been completed
remove the lubricator from the
application.
G-LUBE is an eco-friendly
product that should be
disposed of seperately.
Unscrew the housing cap
counterclockwise to disas-
samble the product for proper
disposal.
Unscrew the srews to remove
the battery cover.
Remove the batteries and
return them for recycling.
Detach the PCB from the unit
using a fl at-head screwdriver.
Dispose of remaining plastic
components according to legal
regulations for recycling.
Do not cut, puncture or reuse
the lubricator.
NOTE
Remove the grease nipple and install proper connectors.
Pull out the mode selector from
the default OFF position (0).
Firmly push the mode selector
into the slot of the desired
period.
When screwing on the housing cap ensure the sealing
ring is fi tted correctly.
NOTE