SEPAMAT F-SC_Manual_Vers.1.0e_en
25
4. Close the air vent.
5. Open the pressure line shut-off valve and flush the air
from the consumer line (e.g. by flushing the toilet
several times or opening the garden tap).
6.
Close all the fixtures.
The pump will now automatically switch off when the
maximum system pressure is reached.
The green LED on the pump controller indicates that the pump is ready to use. In case of a
problem, the red LED will light up (see section 5.1).
The system pressure can be read on the pressure LED indication of the pump controller.
The Automatic Mode or Maintenance Mode can be set via the mode selecting switch.