background image

AC15AFS
Air Filter

Code 106179

Original  Instructions

AT&M: 21/04/2020

BOOK REF: APT008051

BOOK VERSION: 3

Charcoal Outer Filter 

Code 106180

Charcoal Inner Filter

Code 106181

Ceiling Mounting Kit

Code 400398

Replacement Outer 

Filter

Code 106182

Replacement Inner 

Filter

Code 106183

Содержание 106179

Страница 1: ...al Instructions AT M 21 04 2020 BOOK REF APT008051 BOOKVERSION 3 Charcoal Outer Filter Code 106180 Charcoal Inner Filter Code 106181 Ceiling Mounting Kit Code 400398 Replacement Outer Filter Code 106182 Replacement Inner Filter Code 106183 ...

Страница 2: ... North Lai Zhou Road Laizhou Shandong 261400 Shandong China Mainland and complies with the relevant essential health and safety requirements 2006 42 EC EN 292 1 EN 292 2 EN 294 EN 349 EN 55014 EN 60204 1 EN 60335 1 1994 A1 A2 A11 A16 declares that the machinery described This machine complies with the following directives EU Declaration of Conformity EN 60335 2 65 1995 A1 EN 61000 3 2 2000 EN 6100...

Страница 3: ...IONS WORK AREA 1 Keep your work area clean and well lit Cluttered benches and dark areas invite accidents 2 Do not operate electric products in explosive atmospheres such as in the presence of flammable liquids gases or dust 3 Keep bystanders children and visitors away while mounting or maintaining the 3 speed air cleaner ELECTRICAL SAFETY 1 Grounded products must be plugged into an outlet properl...

Страница 4: ...nd use common sense when operating a power product Do not use a power product while tired or under the influence of drugs alcohol or medication 7 Dress properly Do not wear loose clothing or jewelry Contain long hair Keep your hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving parts 8 Avoid accidental starting Be sure the Power Switch is off ...

Страница 5: ...surrounding workspace Always keep the work area free of obstructions grease oil trash and other debris Do not use a power product in areas near flammable chemicals dusts and vapors Do not use this product in a damp or wet location 4 If placing this 3 SPEED AIR CLEANER on a table or shelf make sure that the machine is placed securely on a flat level surface capable of supporting the weight of the m...

Страница 6: ...unded Do not modify the power cord plug provided with the product Never remove the grounding prong from the plug Do not use the product if the power cord or plug is damaged If damaged have it repaired by a service facility before use If the plug will not fit the outlet have a proper outlet installed by a qualified electrician GROUNDED PRODUCT PRODUCTS WITH THREE PRONG PLUGS 1 Products marked with ...

Страница 7: ...you are using an extension cord outdoors make sure it is marked with words to indicate it is acceptable for outdoor use 7 Make sure your extension cord is properly wired and in good electrical condition Always replace a damaged extension cord or have it repaired by a qualified electrician before using it 8 Protect your extension cords from sharp objects excessive heat and damp or wet areas UNPAKCI...

Страница 8: ...r high power twice for medium and three times for low power The corresponding LED will light to show the unit s speed 3 When you are finished using the unit press the off button See Figure B REMOTE CONTRON 27 USAGE 1 Press the On Speed button once for low speed twice for medium and three times for high speed 2 Press the Time button once for 1 hr automatic shut off twice for 2 hour automatic shut o...

Страница 9: ...ssary remove and change the Filter Net 1 On the rear of the unit unlatch the two metal clasps to release the Filter Net 1 Remove the Filter Net 1 and inspect it to see whether it needs a simple cleaning or it needs replacement Reinsert a Filter Net 1 old or new and lock it in place with the two clasps See Figure D Note During this procedure wear ANSI approved safety goggles and dust protection 4 P...

Страница 10: ... Motor will not reach full power 1 Incorrect power wiring 2 Overload 1 Replace incorrect power wiring 2 Reduce load by cleaning filters as necessary Motor overheats 1 Using wrong voltage 2 Motor is damaged 1 Check voltage and voltage label 2 Check and repair the Motor Insufficient suction power 1 Inlet port blocked 2 Filter Bag is full 3 Outlet port blocked 1 Clean inlet port 2 Empty filter bag 3 ...

Страница 11: ... Switch plate 1 6 Main body 1 21 PHLP head screw M4x20 3 7 Rubber foot 4 22 Switch plate label 1 8 Socket hex head screw M5x25 4 23 Power cord 1 9 PHLP head screw M4x8 8 24 Fuse 1 10 Flange 1 25 Strain belief 1 11 Fan 1 26 Hex wrench 3 1 12 Socket hex head screw M4x8 8 27 Remote control 1 13 Fan housing 1 28 Eyelet bolt M4X40 4 14 Rubber shock absorber pad 4 29 Steel chain 4 15 Flat washer 5 4 30 ...

Страница 12: ...ted and recycled separately EU Countries Only The Axminster guarantee is available on Craft Trade Engineer AirTools CNCTechnology Series machines Buy with confidence from Axminster So sure are we of the quality we cover all parts and labour free of charge for three years For more information visit axminstertools com 3years Axminster Tools Axminster Devon EX13 5PH axminstertools com ...

Отзывы: