SEPAMAT F-SC_Manual_Vers.1.0e_en
22
6.3 Installation of the pressure line set
The pressure line set (see section 3) establishes the connection between the pump and pressure
line system.
The pressure line set is connected to the pump
controller.
The flexible hose and the shut-off valve then connect to
the pressure line set and the pressure line.
Attention:
For optimal and efficient pressure control, an expansion
vessel of 5 L is strongly recommended. The primed air
pressure must always be ca. 1 bar under the chosen pump
operating pressure.
Example: The system works with 3 bar, therefore the
primed air pressure should be 2 bar.