Parameter
Description
Off.
Wide Dynamic Level
If WDR is enabled, set the wide dynamic level between 0 and 100.
HLC
Highlight compensation (HLC) is a camera technology that detects if
there are any strong spots of light and compensates for the area as
needed to produce clearer images. Used to read, for example, car
number-plates in streets or parking lots at night. Default is Off.
6. Day/Night Switch
Day/Night Switch
Defines whether the camera is in day or night mode. The day (color)
option could be used, for example, if the camera is located indoors
where light levels are always good. Select one of the options (Default is
Auto):
Day
: Camera is always in day mode.
Night
: Camera is always in night mode.
Auto
: The camera automatically detects which mode to use.
Schedule
: Select the start and end times for day mode
7. White Balance
White Balance
White balance (WB) tells the camera what the color white looks like.
Based on this information, the camera will then continue to display all
colors correctly even when the color temperature of the scene changes
such as from daylight to fluorescent lighting, for example. Select one of
the options (Default is Auto):
MWB
: Manually adjust the color temperature to meet your own
requirements.
Outdoor
: Apply for outdoor environments.
Indoor
: Apply for indoor environments.
Fluorescent Lamp
: Apply for scene where there are fluorescent lamps
installed near the camera.
Sodium Lamp
: Apply for scene where there are incandescent lamps
near the camera.
Auto-Track
: White balance is continuously being adjusted in real-time
according to the color temperature of the scene illumination.
Auto
: White balance is determined automatically.
8. Image Enhancement
Digital Noise Reduction
Digital noise reduction (DNR) reduces noise, especially in low light
conditions, to improve image performance. Select one of the options
(Default is Normal Mode):
Normal Mode
: Standard DNR.
Expert Mode
: Set up the Space DNR level and the Time DNR level.
Space DNR
level is used to reduce static noise, but if you configure a
higher value, the image may be not clear.
Time DNR
level is used to
reduce dynamic noise. If you configure a higher value, the moving object
may have an obvious shadow.
Off
: Disable the function.
Noise Reduction Level
Only available when DNR is set to Normal Mode. Set the level of noise
reduction in the Normal Mode. Higher value has a stronger noise
reduction. Default is 50.
Defog Mode
You can enable the defog function when the environment is foggy and
the image is misty. It enhances the subtle details so that the image
appears clearer. Default is Off.
TruVision Stainless Steel PTZ Camera Configuration Manual