TS25 MKII : TS25-BAS1-KIT : TS25-BAS1-CAN-240
Battery charger/analyser : Operators Manual
Press
PROC
to change the charge mode.
See section 4.4 ENTERING BATTERY DATA for details on how to enter the
required parameters.
4.3.2 LIBRARY CHARGING
To perform a charge from the library the library number has to be selected first.
To select the library number the following procedure has to be performed.
Press the
BATT
key. The display will show the current library item selected and
the rightmost digit will be flashing. Enter the library number by using the
and
keys and the
EXTD
key to move to the next digit. Only library numbers 01 to
99 can be selected.
The unit needs to be placed in charge mode by pressing
CHRG
and ensuring that
the visual indicator
TEST
is extinguished.
4.3.3 REVIEWING CHARGE PARAMETERS
Once these values have been programmed into the unit they can be reviewed by
selecting the
DISP
key to cycle the display between
VOLTS
,
AMPS
and
TIME
and then pressing the
DATA
key. This display will show the values programmed
in and the corresponding indicator will flash. To check the charge mode simply
press the
CHRG
key and the current charge mode will be displayed
CV
,
CC
or
CCA
.
4.3.4 STARTING A CHARGE
Before a charge is performed for the first time it is important that the parameters
are reviewed using the reviewing feature above as incorrect parameters could
damage the battery under charge.
Once satisfied that he data is correct the battery to undergo charging must be
connected to the unit. Care must be taken when connecting batteries which are
not fitted with non reversible connectors, i.e. where the use of crocodile clamps
are implemented, as damage to the battery and or TS25 MKII may occur if a
charge is started in reverse connection.
To begin the charge press
START
. The display will momentarily display
RUN
, the
END
light will extinguish and it will then display battery voltage. During the
normal charge process the
DISP
key may be pressed to cycle the display
between
VOLTS
,
AMPS
and
TIME
. The
DATA
key can also be pressed to review
the parameters programmed in for the current test under progress. Pressing the
CHRG
key will also briefly display the current charge mode.
4.3.5 STOPPING A CHARGE
At any time during the charge the process can be terminated by simply pressing
the
STOP
key. When the
STOP
key is pressed the process will be terminated
Doc: DWG1044-09-R16 TS25 MKII Operators manual.odt